Results 191 to 200 of about 11,574,340 (406)
Summary In this contribution, we propose a detailed study of interpolation‐based data‐driven methods that are of relevance in the model reduction and also in the systems and control communities. The data are given by samples of the transfer function of the underlying (unknown) model, that is, we analyze frequency‐response data.
Quirin Aumann, Ion Victor Gosea
wiley +1 more source
Abstract Purpose Palliative radiotherapy comprises a significant portion of the radiation treatment workload. Volumetric‐modulated arc therapy (VMAT) improves dose conformity and, in conjunction with flattening filter free (FFF) delivery, can decrease treatment times, both of which are desirable in a population with a high probability of retreatment ...
Madeleine L. Van de Kleut+2 more
wiley +1 more source
Data‐driven performance metrics for neural network learning
Summary Effectiveness of data‐driven neural learning in terms of both local mimima trapping and convergence rate is addressed. Such issues are investigated in a case study involving the training of one‐hidden‐layer feedforward neural networks with the extended Kalman filter, which reduces the search for the optimal network parameters to a state ...
Angelo Alessandri+2 more
wiley +1 more source
Protocol Data Units For Distributed Interactive Simulation: Military Standard (draft) [PDF]
Report contains requirements for a communication protocol between simulated entities in a distributed interactive ...
University of Central Florida Institute for Simulation and Training
core +1 more source
Evaluation of the effect of metal stents on dose perturbation in the carbon beam irradiation field
Abstract Propose Carbon ion therapy is indicated for cases in which stents have been inserted, such as bile ducts, but the effect of metal stents on carbon ion therapy is unclear. In this study, the dose perturbation of carbon ion therapy caused by metallic bile duct stents was evaluated by dosimetry. Materials and methods Five different types of metal
Yuya Miyasaka+8 more
wiley +1 more source
Simulator Ensembles for Trustworthy Autonomous Driving Testing [PDF]
Scenario-based testing with driving simulators is extensively used to identify failing conditions of automated driving assistance systems (ADAS) and reduce the amount of in-field road testing. However, existing studies have shown that repeated test execution in the same as well as in distinct simulators can yield different outcomes, which can be ...
arxiv
Die Simulation psychischer Krankheitszustände-in militärforensischer Beziehung [PDF]
Mönkemöller
openalex +1 more source
Communication Architecture For Distributed Interactive Simulation (CADIS): Rationale Document Draft [PDF]
Report on necessary communication system protocol data unit standards which must be accepted and adopted for supporting distributed interactive ...
University of Central Florida Institute for Simulation and Training
core +1 more source
Abstract Purpose The dual‐layer multileaf collimator (MLC) in Halcyon adds complexities to the dose calculation process owing to the variability of dosimetric characteristics with leaf motion. Recently, an enhanced leaf model (ELM) was developed to refine the MLC model in the Eclipse treatment planning system. This study investigates the performance of
Ryohei Miyasaka+6 more
wiley +1 more source