Results 41 to 50 of about 6,439,042 (312)

An experimental analysis on the performance of single mode-multimode-single mode and multimode- single mode-multimode fiber optic sensor [PDF]

open access: yesMalaysian Journal of Fundamental and Applied Sciences, 2019
A cost effective and simple fabrication process for Mach Zehnder Interferometer (MZI) fiber based sensor has been proposed based on single mode-multimode-single mode structure and multimode-single mode-multimode. These proposed structures employed a standard fusion arc splicing by varying the length of sensing region instead of the structures.
openaire   +1 more source

ibegleris/Single-mode-FOPO: First public release

open access: yes, 2017
<p>This code simulates a single mode Fibre Optical Parametric Oscillator using Python 3.6. The theory regarding the project has been presented and shown in Numerical Simulations of Optoelectronic Devices Copenhagen 2017 and Frontiers In optics ...
Peter Horak   +3 more
core   +1 more source

Deep Sequencing of FLT3‐ITD Enables Response Evaluation and Post‐Treatment Monitoring in Childhood AML: An Exploratory Study

open access: yesPediatric Blood &Cancer, EarlyView.
ABSTRACT Background An internal tandem duplication in the gene encoding Fms‐like tyrosine kinase 3 (FLT3‐ITD) is associated with high relapse risk and poor prognosis in acute myeloid leukemia (AML) and plays a crucial role in treatment decisions. Measurable residual disease (MRD) analysis of FLT3‐ITD during and after treatment has shown prognostic ...
Sofie Johansson Alm   +11 more
wiley   +1 more source

High power cladding-pumped Raman fiber laser with true single-mode output at 1660 nm

open access: yes, 2006
We report a 10 W continuous-wave cladding-pump Raman fiber laser with single-mode output at 1660 nm pumped by a high-power Er:Yb fiber amplifier. The laser threshold was 6.5 W and its slope efficiency was 67%
Jeong, Y.   +11 more
core   +1 more source

Single-factor analysis curve of 60min disintegration regression mode.

open access: yes, 2023
Single-factor analysis curve of 60min disintegration regression mode.
Gui-yao Wang (9931919)   +3 more
core   +1 more source

Efficacy and Safety Analysis of Roxarestat in Regulating Renal Anemia in Patients on Maintenance Hemodialysis

open access: yesTherapeutic Apheresis and Dialysis, EarlyView.
ABSTRACT Objective To compare the efficacy and safety of roxarestat versus recombinant human erythropoietin (rhEPO) in the management of renal anemia in patients undergoing maintenance hemodialysis. Methods This was a prospective, open‐label, randomized controlled trial.
Lingling Chen, Junjie Zhu, Qiaonan Ge
wiley   +1 more source

Mode dispersion and delay characteristics of optical waveguides using equivalent TL circuits [PDF]

open access: yes, 2005
A new analysis leading to an exact and efficient algorithm is presented for calculating directly and without numerical differentiation the mode dispersion characteristics of cylindrical dielectric waveguides of arbitrary refractive-index profile. The new
Boucouvalas, Anthony C., Qian, Xin
core   +1 more source

Effects of the Fluid Replacement Method During Online Hemodiafiltration on the Solute Removal Performance and Biocompatibility Using the Asymmetric Cellulose Triacetate Membrane

open access: yesTherapeutic Apheresis and Dialysis, EarlyView.
ABSTRACT Introduction Pre‐dilution online hemodiafiltration (Pre‐HDF) is predominantly used in Japan, whereas post‐dilution online HDF (Post‐HDF) is more common in Europe. An asymmetric cellulose triacetate (ATA) membrane may improve biocompatibility.
Kenji Sakurai   +4 more
wiley   +1 more source

Strain sensor based on gourd-shaped single-mode-multimode-single-mode hybrid optical fibre structure

open access: yes, 2017
A fibre-optic strain sensor based on a gourd-shaped joint multimode fibre (MMF) sandwiched between two single-mode fibres (SMFs) is described both theoretically and experimentally.
Haidong Liang   +24 more
core   +1 more source

Experience With Performing Rheocarna Therapy via the Single‐Needle Method for Treatment of Chronic Limb‐Threatening Ischemia

open access: yesTherapeutic Apheresis and Dialysis, EarlyView.
ABSTRACT Introduction This study investigated the safety and efficacy of single‐needle Rheocarna therapy for chronic limb‐threatening ischemia (CLTI) with wounds. Methods Six patients with CLTI involving ulcers unresponsive to revascularization underwent single‐needle Rheocarna treatment.
Yasutaka Yamauchi   +9 more
wiley   +1 more source

Home - About - Disclaimer - Privacy