Simulation of single-phase ground short circuit protection device [PDF]

open access: diamondE3S Web of Conferences, 2021
The most common type of short circuit in a three-phase system is a single-phase-to-ground short circuit, accounting for 70 to 90% of electrical faults.
Zhumadirova Aliya   +2 more
doaj   +3 more sources

Currents in the overhead transmission line lighting wire in case of single-phase short circuit [PDF]

open access: diamondE3S Web of Conferences, 2018
The algorithms for currents induced in a grounded lightning wire (LW) with single-phase short circuit (SC) calculation are considered. It is shown that the method of short-circuit current and current in LW simultaneous determination gives more correct ...
Zimin Kirill   +3 more
doaj   +4 more sources

Mathematical Modelling of Transient Processes in a Three Phase Electric Power System for a Single Phase Short-Circuit [PDF]

open access: goldEnergies, 2022
Field approaches are employed to develop a mathematical model of a power network section. The facility consists of two electric power subsystems described with ordinary differential equations and presented as concentrated parameter systems connected with
Andriy Chaban   +3 more
doaj   +4 more sources

Correction of methods for calculating the single-phase short circuit current in a rural 0.4 kv electric grid

open access: diamondИзвестия высших учебных заведений: Проблемы энергетики
The relevance of the study lies in the consideration and correction of the results of calculations of the single-phase short circuit current in a rural 0.4 kV electric network obtained using existing physical, computer and mathematical methods that give ...
A. A. Lansberg, A. V. Vinogradov
doaj   +3 more sources

INVESTIGATION AND CALCULATION OF VALLEYS OF OUTGOING FROM SUBSTATION GROUNDING CONDUCTORS FOR SHORT-CIRCUIT IN SINGLE-PHASE SHORT OF ELECTRICAL GRID

open access: goldElectrical engineering & Electromechanics, 2015
Introduction. Earthing device electrical substation in modern conditions must meet both the requirements of electrical safety of people and animals, as well as electromagnetic compatibility requirements established her electrical equipment.
V. I. Nizhevskyi   +3 more
doaj   +3 more sources

Reason Analysis for the increase of single-phase short circuit current and its suppressing measure [PDF]

open access: goldProceedings of the 4th International Conference on Information Technology and Management Innovation, 2015
KEYWORD: Single-phase short circuit current; Neutral grounding; Small reactance; Autotransformer ABSTRACT: Aiming at the issue that the single-phase short circuit current at the 220 kV bus of Chengdu 500kV substation exceeds the three-phase short current or even exceeds the breaking capacity of breaker, the reason is analyzed and the measure that main ...
G. Chen, H. Zhang, Y. Li
openaire   +3 more sources

Contributions of single-phase rooftop PVs on short circuits faults in residential feeders [PDF]

open access: green2014 Australasian Universities Power Engineering Conference (AUPEC), 2014
Sensitivity analysis results are presented to investigate the presence of single-phase rooftop Photovoltaic Cells (PV) in low voltage residential feeders, during short circuits in the overhead lines. The PV rating and location in the feeder and the fault location are considered as the variables of the sensitivity analysis.
Syed Islam   +2 more
openaire   +4 more sources

Research on the Distribution Network’s Single-phase Short-circuit Faults with Wavelet Transform [PDF]

open access: goldAdvances in Intelligent Systems Research, 2015
According to the problem that the single phase grounding fault location is difficult to detect, a novel method of identifying fault line for single phase grounding fault is presented, based on the detailed analysis of the transient zero sequence network's fault characteristics in the small current neutral grounding power system.
Yan Xu, Hongyuan Huang
openaire   +3 more sources

Disconnection of single-phase rooftop PVs after short-circuit faults in residential feeders

open access: greenAustralian Journal of Electrical and Electronics Engineering, 2016
AbstractThis paper presents an analysis on the disconnection time of single-phase rooftop photovoltaic systems (PVs), located in a three-phase four-wire low voltage distribution feeder, after a single-phase and a three-phase short-circuit fault on the low-voltage feeder.
Hosseinian Yengejeh, H.   +2 more
openaire   +5 more sources

Simulation and Analysis of Internal Short Circuit Fault, Electromagnetic Forces and Thermal Analysis of Single Phase Transformer [PDF]

open access: green, 2022
Transformer is an essential part of power system which is a vital link between generating station and the utilities. The failure of the transformer results into huge loss of revenue. If the cause of the failure is detected at early stage then the transformer can be saved from complete outage which also increases the reliability of the supply.
Krishna Patel
openaire   +3 more sources