Results 11 to 20 of about 501,948 (340)
Solar Photovoltaic (PV) system consists of three main parts which are PV array, PV inverter and utility grid. From the three, PV inverter is considered the weakest link in the solar PV system. Insulated Gate Bipolar Transistor (IGBT) is the most critical component in an inverter and is often blamed for the failure of inverters.
Z. A. M. Sharrif +2 more
openaire +3 more sources
Method for Restricting Grid Single-Phase Short-Circuit Current [PDF]
Jingyan Liu, Wenying Liu, Li Xiaorong
openaire +2 more sources
{"references": ["M. S: Mami\u015f and A. Nacaro\u011flu, \"Transient voltage and current distributions on transmission lines\", IEE Proc. Gener. Trans. Distrib. Vol. 149, No. 6, November 2002.", "S Kurokawa, F. N. R. Yamanaka, A. J Prado, \"Inclusion of the frequency effect in the lumped parameters transmission line model: State space formulation ...
A. Kojah, A. Nacaroğlu
openaire +2 more sources
Experimental study of transients under single-phase short circuits in the 20 kV network
А.V. Mayorov +2 more
openaire +2 more sources
COMPARISON OF SINGLE PHASE SHORT CIRCUIT MODELLING BY USING OF ATPDRAW SOFTWARE AND IEC PROCEDURES [PDF]
Increasing trends of energy consumption and urban constraints in construction of new transmission/distribution substations are indications of bigger short circuit currents on busbars and overhead lines (OHL). OHLs are commonly equipped with Optical Power Ground Wire (OPGW), which has its limitations based on short circuit withstand heat impulse—heat ...
Aleksandar Terzić, Aleksandar Terzić
openaire +2 more sources
Analysis of Sudden Short Circuit Faults In 5KVA Single Phase Synchronous Generator. [PDF]
Eleje Nelson Emeka, Ezema Edwin Ejiofor
openaire +2 more sources
Design and application of short circuit test scheme for Hu Zhou DPFC project
The short circuit test of distributed power flow controller (DPFC) is still a blank in the world. In order to test the effectiveness and adaptability of DPFC in case of line failure, it is necessary to carry out short circuit tests in DPFC projects ...
Qian Chen +5 more
doaj +1 more source
The article deals with the problems of single-phase short-circuit current distribution in overhead power lines. Short-circuit disturbances cause many negative phenomena in power networks.
Rafał Tarko +3 more
doaj +1 more source
Fault detection technology for intelligent boundary switch [PDF]
An intelligent boundary switch is a three-phase outdoor power distribution device equipped with a controller. It is installed at the boundary point on the medium voltage overhead distribution lines.
Ling Liu
doaj +1 more source
A short circuit current evaluation method based on the branch fault current of the circuit breaker
With the rapid load growth and the increasing density of power grids, the overrun short-circuit current becomes increasingly aggravated. To accurately assess the short-circuit current level of the system is crucial to ensure the safe and stable operation
DONG Wei +5 more
doaj +1 more source

