Nanosecond-level time-domain coding metasurface for radar signal generation. [PDF]
Qian B +6 more
europepmc +1 more source
Measuring central charge on a universal quantum processor. [PDF]
Köylüoğlu NU +7 more
europepmc +1 more source
Effects of Neutral Point Grounding Methods on Single-Phase Short Circuit Fault Characteristics
Amela Kokor +3 more
openaire +2 more sources
Influence of neutral earthing on single-phase short-circuit currents
J. Schlabbach
openaire +2 more sources
Some of the next articles are maybe not open access.
Related searches:
Related searches:
Influence of single-phase short circuit to TWACS signal
2013 International Conference on Quality, Reliability, Risk, Maintenance, and Safety Engineering (QR2MSE), 2013Previous TWACS models are proposed for no electric power system fault conditions and don't involve the transmission of power system under fault condition. This paper studies the running state and signal detection of TWACS under the condition of single-phase short circuit condition in neutral point ineffectively grounded power system.
Zongye Liu +3 more
openaire +1 more source
Single-phase short-circuit torque
Electrical Engineering, 1932The analysis of synchronous machines previously published by Doherty and Nickle is expanded in this article to include the calculation of torque due to single-phase short-circuit. The torque is expressed as the sum of odd and even harmonic series which are simply related to those previously derived for the armature current.
C. A. Nickle +2 more
openaire +1 more source
Single-phase short-circuit torque of a synchronous machine
Electrical Engineering, 1932This paper extends the analysis of synchronous machines previously published by Doherty and Nickle to include the calculation of torque due to single-phase short circuit. The torque is expressed as the sum of odd and even harmonic series which are simply related to those previously derived for the armature current. The effect of amortisseur windings is
C. A. Nickle +2 more
openaire +1 more source
Stability of Synchronous Motors Under Single Phase Grid Short Circuits
2018 International Multi-Conference on Industrial Engineering and Modern Technologies (FarEastCon), 2018This paper studies asymmetrical voltage sags caused by single phase short circuits appearing in power grids. Research defines the worst case fault conditions and shows their impact on stability of high voltage synchronous motors. Calculations done within the research take into account the distribution of voltage and current symmetrical components in ...
A. I. Fedotov, R. M. Mudarisov
openaire +1 more source