2021 11th International Conference on Power and Energy Systems (ICPES), 2021
Xiaoxiao Luo+5 more
openaire +1 more source
Xiaoxiao Luo+5 more
openaire +1 more source
IEEE Transactions on Energy Conversion, 1997
This work presents a method of general two-phase harmonic symmetrical components, for the analysis and calculation of single-phase induction motor characteristics with shaded poles and two short circuited auxiliary phases. The method is based on rotating field theory applying the harmonic symmetrical current components of direct and inverse order. Thus,
D. Basic, J. Varga
openaire +2 more sources
This work presents a method of general two-phase harmonic symmetrical components, for the analysis and calculation of single-phase induction motor characteristics with shaded poles and two short circuited auxiliary phases. The method is based on rotating field theory applying the harmonic symmetrical current components of direct and inverse order. Thus,
D. Basic, J. Varga
openaire +2 more sources
2019 22nd International Conference on Electrical Machines and Systems (ICEMS), 2019
This paper investigates the effects of single-phase short-circuit faults (SCF) on the electromagnetic (EM) force and vibration compared with the normal condition of the motor. Firstly, this paper introduces the structure of the modular motor. Secondly, optimize the modular motor structure to suppress the short-circuit current and ensure that the motor ...
Shibo Li+5 more
openaire +2 more sources
This paper investigates the effects of single-phase short-circuit faults (SCF) on the electromagnetic (EM) force and vibration compared with the normal condition of the motor. Firstly, this paper introduces the structure of the modular motor. Secondly, optimize the modular motor structure to suppress the short-circuit current and ensure that the motor ...
Shibo Li+5 more
openaire +2 more sources
2019 IEEE Asia Power and Energy Engineering Conference (APEEC), 2019
For double or multiple circuits of 1000kV lines on the same tower, where a permanent single-phase ground fault occurs on one circuit, delayed current zero crossing may take place during single-phase reclosing of circuit breaker. This may overburden and even damage the breaker.
Zha Zhipeng+3 more
openaire +2 more sources
For double or multiple circuits of 1000kV lines on the same tower, where a permanent single-phase ground fault occurs on one circuit, delayed current zero crossing may take place during single-phase reclosing of circuit breaker. This may overburden and even damage the breaker.
Zha Zhipeng+3 more
openaire +2 more sources
Investigation of single phase short circuits and reverse current relay connections and operation
James Lawton Ellis
openalex
Power Supply of Three-Phase Testing Transformer for Single-Phase Short-Circuit Test
Wang Cunling
openalex
A New Method to Restrict the Single-phase Short-circuit Current of the Transmission
Hao Guo-fa
openalex