Results 41 to 50 of about 494,648 (339)
In hierarchically connected UHV DC projects, the 1000 kV AC filter sub-bank in converter station is provided with two 500 kV circuit breakers. To determine the test DC component decay time constant when breakers break short-circuit current, relevant DC ...
Li Zhenqiang +3 more
doaj +1 more source
Study on the Influence of Reignition on Electrical Life Distribution of Low-Voltage Circuit Breakers
This study analyzes the recovery voltage changes when a low-voltage circuit breaker opens with load and short-circuit faults and explains the reignition types under different recovery voltages.
Zhengjun Liu +2 more
doaj +1 more source
Fast synchronization 3R burst-mode receivers for passive optical networks [PDF]
This paper gives a tutorial overview on high speed burst-mode receiver (BM-RX) requirements, specific for time division multiplexing passive optical networks, and design issues of such BM-RXs as well as their advanced design techniques. It focuses on how
Bauwelinck, Johan +8 more
core +2 more sources
This paper discusses the problem associated with accidents in the aerial line (AL) ultra-high voltage (UHV) due to its big length. In lines with a voltage of 500-1150 kV the overwhelming proportion of trips (98%) is caused by single-phase short circuit ...
Krasil'nikova Tatyana, Jononaev Saiyod
doaj +1 more source
Contributions of single-phase rooftop PVs on short circuits faults in residential feeders
Sensitivity analysis results are presented to investigate the presence of single-phase rooftop Photovoltaic Cells (PV) in low voltage residential feeders, during short circuits in the overhead lines. The PV rating and location in the feeder and the fault location are considered as the variables of the sensitivity analysis.
Hadi Hosseinian Yengejeh +2 more
openaire +2 more sources
A Sensitivity Method for Assessing the Impact of Generator/Transformer Impedance upon Power System Fault Behaviour [PDF]
An analytical method is presented for determining the potential impact that the connection of a single new generator may have upon the performance of a transmission system under balanced three-phase fault conditions.
McDonald, J. D. F., Saha, Tapan K.
core +1 more source
Short circuit study of fixed speed wind turbines with STATCOM in distribution networks [PDF]
The increased penetration of wind farm in distribution networks has brought changes in the performance of the whole system. Such disadvantages when connecting one of these distributed generation sources is reduced voltage and power stability of the AC ...
Darwish, M, Naain, MM, Zobaa, AF
core +1 more source
Analysis of Voltage Sag Due to Short Circuit on the Sub System in Central Sumatera
Power quality is closely related to electrical energy which is directly related to voltage and current interference. Electrical equipment used daily requires good power quality. The thing that affects the quality of the power is the voltage dip. Based on
Hamzah Eteruddin +2 more
doaj +1 more source
This paper studies a real 36-MW large tubular hydro-generator to solve the transient variation problem of the loss and heat of damper bars during short circuit faults in tubular hydro-generators.
Qing-Ling Hu +7 more
doaj +1 more source