Results 51 to 60 of about 566,628 (336)
Unfaithful Glitch Propagation in Existing Binary Circuit Models [PDF]
We show that no existing continuous-time, binary value-domain model for digital circuits is able to correctly capture glitch propagation. Prominent examples of such models are based on pure delay channels (P), inertial delay channels (I), or the ...
Függer, Matthias+2 more
core +4 more sources
This paper discusses the problem associated with accidents in the aerial line (AL) ultra-high voltage (UHV) due to its big length. In lines with a voltage of 500-1150 kV the overwhelming proportion of trips (98%) is caused by single-phase short circuit ...
Krasil'nikova Tatyana, Jononaev Saiyod
doaj +1 more source
Application of multiple resistive superconducting fault-current limiters for fast fault detection in highly interconnected distribution systems [PDF]
Superconducting fault-current limiters (SFCLs) offer several benefits for electrical distribution systems, especially with increasing distributed generation and the requirements for better network reliability and efficiency.
Blair, Steven Macpherson+3 more
core +1 more source
This paper studies a real 36-MW large tubular hydro-generator to solve the transient variation problem of the loss and heat of damper bars during short circuit faults in tubular hydro-generators.
Qing-Ling Hu+7 more
doaj +1 more source
Short circuit study of fixed speed wind turbines with STATCOM in distribution networks [PDF]
The increased penetration of wind farm in distribution networks has brought changes in the performance of the whole system. Such disadvantages when connecting one of these distributed generation sources is reduced voltage and power stability of the AC ...
Darwish, M, Naain, MM, Zobaa, AF
core +1 more source
Analysis of Voltage Sag Due to Short Circuit on the Sub System in Central Sumatera
Power quality is closely related to electrical energy which is directly related to voltage and current interference. Electrical equipment used daily requires good power quality. The thing that affects the quality of the power is the voltage dip. Based on
Hamzah Eteruddin+2 more
doaj +1 more source
Exposure to common noxious agents (1), including allergens, pollutants, and micro‐nanoplastics, can cause epithelial barrier damage (2) in our body's protective linings. This may trigger an immune response to our microbiome (3). The epithelial barrier theory explains how this process can lead to chronic noncommunicable diseases (4) affecting organs ...
Can Zeyneloglu+17 more
wiley +1 more source
New mathematical model for analysing three-phase controlled rectifier using switching functions [PDF]
This paper is a postprint of a paper submitted to and accepted for publication in IET Power Electronics and is subject to Institution of Engineering and Technology Copyright. The copy of record is available at IET Digital Library.The aim of this study is
Alesina+6 more
core +1 more source
Current trends in single‐cell RNA sequencing applications in diabetes mellitus
Single‐cell RNA sequencing is a powerful approach to decipher the cellular and molecular landscape at a single‐cell resolution. The rapid development of this technology has led to a wide range of applications, including the detection of cellular and molecular mechanisms and the identification and introduction of novel potential diagnostic and ...
Seyed Sajjad Zadian+6 more
wiley +1 more source
Research on Safety Technology for High-Speed Interruption for Mining Flameproof Movable Substation
Due to the working condition of low-voltage cabling from the mining flameproof movable substation to the loads of the mining face being poor, it is easy to cause various external mechanical damages to the cable sheaths.
Yanwen Wang+3 more
doaj +1 more source