Results 191 to 200 of about 3,081 (308)

Hölder Regularity of the Solutions of Fredholm Integral Equations on Upper Ahlfors Regular Sets

open access: yesMathematical Methods in the Applied Sciences, EarlyView.
ABSTRACT We extend to the context of metric measured spaces, with a measure that satisfies upper Ahlfors growth conditions, the validity of (generalized) Hölder continuity results for the solution of a Fredholm integral equation of the second kind. Here we note that upper Ahlfors growth conditions include also cases of nondoubling measures.
Massimo Lanza de Cristoforis   +1 more
wiley   +1 more source

On Compressible Fluid Flows of Forchheimer‐Type in Rotating Heterogeneous Porous Media

open access: yesMathematical Methods in the Applied Sciences, EarlyView.
ABSTRACT We study the dynamics of compressible fluids in rotating heterogeneous porous media. The fluid flow is of Forchheimer‐type and is subject to a mixed mass and volumetric flux boundary condition. The governing equations are reduced to a nonlinear partial differential equation for the pseudo‐pressure.
Emine Celik, Luan Hoang, Thinh Kieu
wiley   +1 more source

Four Directions, One Solution: Enabling Rapid Diffusion Tensor MRI for Ultra‐Low Field Using Deep Learning

open access: yesMagnetic Resonance in Medicine, EarlyView.
ABSTRACT Purpose This study revisits the tetrahedral encoding strategy originally proposed to accelerate Diffusion Tensor Magnetic Resonance Imaging (DT‐MRI) by reducing the requisite number of diffusion‐weighted measurements to four. We examine its practical limitations and explore how artificial intelligence (AI) can extend its utility. Specifically,
Joshua Mawuli Ametepe   +4 more
wiley   +1 more source

Reducing Motion Artifact in High Resolution 7 T MRI Using the Magnetic Resonance Minimal Motion (“MR‐MinMo”) Head Stabilization Device

open access: yesMagnetic Resonance in Medicine, EarlyView.
ABSTRACT Purpose To evaluate the effectiveness of the MR‐MinMo head stabilization device in mitigating motion artifacts during long‐duration, high‐resolution 7 T MRI scans, with and without retrospective motion correction Methods The MR‐MinMo was tested on seven pediatric and 12 adult healthy volunteers using 0.6 mm isotropic, 3D Multi‐Echo Gradient ...
Jyoti Mangal   +10 more
wiley   +1 more source

Simultaneous T2, T2*, and R2′ Mapping for Multiple Sclerosis Using Nonlinear Model‐Based Reconstruction of Undersampled Radial RARE‐EPI MRI

open access: yesMagnetic Resonance in Medicine, EarlyView.
ABSTRACT Purpose To demonstrate the synergy of undersampled radial 2in1‐RARE‐EPI acquisition and nonlinear model‐based reconstruction for accelerated and simultaneous T2, T2*, and R2′ mapping in brains of patients with multiple sclerosis (MS). Methods 2in1‐RARE‐EPI combines a RARE module with an EPI module to capture T2 and T2* information.
Jose Raul Velasquez Vides   +16 more
wiley   +1 more source

Home - About - Disclaimer - Privacy