Results 161 to 170 of about 149,384 (349)

Emergency department prescription of sinus rhythm maintenance therapy for patients treated for atrial fibrillation: a secondary analysis of the HERMES-AF study [PDF]

open access: diamond
Amparo Fernández‐Simón   +11 more
openalex   +1 more source

Acute Efficacy of Pulsed‐Field Ablation of the Mitral Isthmus Using a Pentaspline Catheter and Two Different Ablation Settings

open access: yesJournal of Cardiovascular Electrophysiology, EarlyView.
ABSTRACT Introduction There is limited data regarding the use of pulsed‐field ablation (PFA) for mitral isthmus (MI) ablation in patients with non‐paroxysmal atrial fibrillation (AF). Our aim was to assess the acute efficacy of MI ablation using a pentaspline PFA catheter with two different ablation settings.
Josef Hornof   +13 more
wiley   +1 more source

Averaged Impedance Drop Estimates Conduction Gap During Pulmonary Vein Isolation in Atrial Fibrillation

open access: yesJournal of Cardiovascular Electrophysiology, EarlyView.
ABSTRACT Background EnSite X provides a module to filter oscillated generator impedance signals due to cardiac beating/respiration (averaged impedance drop, AID). TactiFlex ablation catheter Sensor Enabled (TFSE) is the latest product to incorporate a contact‐force sensor with a flexible tip but without lesion‐estimating parameters.
Masahide Harada   +6 more
wiley   +1 more source

Effect of Sacubitril-Valsartan on Restoration and Maintenance of Sinus Rhythm in Patients With Persistent Atrial Fibrillation [PDF]

open access: gold, 2022
Qingsong Chen   +12 more
openalex   +1 more source

Impact of Pulsed Field Ablation Dosing on Outcome After Pulmonary Vein Isolation Using a Pentaspline Ablation Catheter: A Prospective Comparison of 8 Versus 16 Applications

open access: yesJournal of Cardiovascular Electrophysiology, EarlyView.
ABSTRACT Background Pulsed field ablation (PFA) is a novel, non‐thermal ablation modality to achieve pulmonary vein isolation (PVI) for the treatment of atrial fibrillation (AF). For the pentaspline catheter, eight applications per pulmonary vein (PV) are considered standard, with four in basket configuration and four in flower configuration.
Katharina Ji‐Mi Yang   +8 more
wiley   +1 more source

Dancing Bundles With Stable Sinus Rhythm [PDF]

open access: yesCirculation, 2022
Jaya Batra   +2 more
openaire   +2 more sources

Mechanical dyssynchrony of the left atrium during sinus rhythm is associated with history of stroke in patients with atrial fibrillation [PDF]

open access: bronze, 2017
Luisa Ciuffo   +11 more
openalex   +1 more source

Role of a Deep‐Learning Based Convolutional Neural Network Model for Real‐Time Ventricular Tachycardia Alarm Classification

open access: yesJournal of Cardiovascular Electrophysiology, EarlyView.
Our manuscript discusses the role of a Convolutional Neural network based Deep‐learning model for the classification of ventricular tachycardia alarms. Our algorithm based on input from multiple raw waveform inputs, including electrocardiogram leads, photoplethysmogram, and arterial blood pressure signals achieved a good degree of accuracy and ...
Unmesh Khanolkar   +5 more
wiley   +1 more source

Long‐Term Follow‐Up of Radiofrequency Slow Pathway Ablation for Atrioventricular Nodal Re‐Entrant Tachycardia: Late Outcomes

open access: yesJournal of Cardiovascular Electrophysiology, EarlyView.
ABSTRACT Introduction Slow pathway radiofrequency ablation is an effective treatment for atrioventricular nodal re‐entrant tachycardia (AVNRT) but has been reported in some series to result in late atrioventricular block. We examined our local experience with a retrospective review. Methods A retrospective review of all patients undergoing slow pathway
Emma Yaakop   +9 more
wiley   +1 more source

Home - About - Disclaimer - Privacy