Results 161 to 170 of about 149,384 (349)
Emergency department prescription of sinus rhythm maintenance therapy for patients treated for atrial fibrillation: a secondary analysis of the HERMES-AF study [PDF]
Amparo Fernández‐Simón +11 more
openalex +1 more source
ABSTRACT Introduction There is limited data regarding the use of pulsed‐field ablation (PFA) for mitral isthmus (MI) ablation in patients with non‐paroxysmal atrial fibrillation (AF). Our aim was to assess the acute efficacy of MI ablation using a pentaspline PFA catheter with two different ablation settings.
Josef Hornof +13 more
wiley +1 more source
ABSTRACT Background EnSite X provides a module to filter oscillated generator impedance signals due to cardiac beating/respiration (averaged impedance drop, AID). TactiFlex ablation catheter Sensor Enabled (TFSE) is the latest product to incorporate a contact‐force sensor with a flexible tip but without lesion‐estimating parameters.
Masahide Harada +6 more
wiley +1 more source
Effect of Sacubitril-Valsartan on Restoration and Maintenance of Sinus Rhythm in Patients With Persistent Atrial Fibrillation [PDF]
Qingsong Chen +12 more
openalex +1 more source
ABSTRACT Background Pulsed field ablation (PFA) is a novel, non‐thermal ablation modality to achieve pulmonary vein isolation (PVI) for the treatment of atrial fibrillation (AF). For the pentaspline catheter, eight applications per pulmonary vein (PV) are considered standard, with four in basket configuration and four in flower configuration.
Katharina Ji‐Mi Yang +8 more
wiley +1 more source
Dancing Bundles With Stable Sinus Rhythm [PDF]
Jaya Batra +2 more
openaire +2 more sources
Mechanical dyssynchrony of the left atrium during sinus rhythm is associated with history of stroke in patients with atrial fibrillation [PDF]
Luisa Ciuffo +11 more
openalex +1 more source
Our manuscript discusses the role of a Convolutional Neural network based Deep‐learning model for the classification of ventricular tachycardia alarms. Our algorithm based on input from multiple raw waveform inputs, including electrocardiogram leads, photoplethysmogram, and arterial blood pressure signals achieved a good degree of accuracy and ...
Unmesh Khanolkar +5 more
wiley +1 more source
Impact of ivabradine on dyspnea in patient with moderate mitral stenosis in sinus rhythm
Geetha Subramanian +2 more
openalex +1 more source
ABSTRACT Introduction Slow pathway radiofrequency ablation is an effective treatment for atrioventricular nodal re‐entrant tachycardia (AVNRT) but has been reported in some series to result in late atrioventricular block. We examined our local experience with a retrospective review. Methods A retrospective review of all patients undergoing slow pathway
Emma Yaakop +9 more
wiley +1 more source

