Slab-column edge connections subjected to high moments
Canadian Journal of Civil Engineering, 1998This paper presents test results of eight large-scale reinforced concrete flat plate edge connections. The test specimens consisted of two identical series. Each series consisted of four specimens, two with openings, in the vicinity of the column, and the other two without openings.
E F El-Salakawy, M A Polak, M H Soliman
openaire +1 more source
An Experimental Study of Slab-Column Connections
ACI Structural Journal, 1992Four slab-column subassemblages, modeled after a typical reinforced flat plate building, are tested under combined gravity and lateral loads. The testing program incorporates two levels of gravity loads and compares the effects of biaxial versus uniaxial lateral loading on connection behavior. To study the effectiveness of connection repair, one of the
openaire +1 more source
Lattice Shear Reinforcement for Slab-Column Connections
ACI Structural Journal, 2007The research presented herein was carried out with the financial support of Dongbu Corporation Jeil Technos Corporation, and The Ministry of Construction & Transportation of Korea (04R&D C02-02).
openaire +1 more source
Seismic Design Issue of Corner Slab-Column Connection
Journal of Earthquake Engineering, 2013Design criteria of slab-column connections in the ACI Building Code [2011] were mostly developed from experimental results of interior connections. When dealing with corner slab-column connections, supplementary documents published by ACI Committee 352 and Committee 421 provide better explanations than the ACI Building Code [2011] and become useful ...
Min-Yuan Cheng, Marnie B. Giduquio
openaire +1 more source
Seismic Design Criteria for Slab-Column Connections
ACI Structural Journal, 2007Two-way slabs without beams are popular floor systems because of their relatively simple formwork and the potential for shorter story heights. Earthquakes, however, have demonstrated that slab-column frames are vulnerable to brittle punching shear failures in the slab-column connection region and dropping of the slab, which are costly to repair.
openaire +1 more source
Cyclic Lateral Loading of Nonductile Slab-Column Connections
ACI Structural Journal, 2006Flat slabs with discontinuous bottom reinforcement are susceptible to progressive collapse if punching shear failure occurs at a slab-column connection. Many such failures have occurred in past earthquakes, resulting in significant loss of life. The evaluation of older flat-slab buildings must include a realistic prediction of the response of the slab ...
openaire +1 more source
Repair and Strengthening of Reinforced Concrete Slab-Column Connections
IABSE Congress, Chicago 2008: Creating and Renewing Urban Structures – Tall Buildings, Bridges and Infrastructure, 2008<p>Seven 2/3-scale interior slab-column connections were tested to quantify the effects of earthquake damage, and the efficiency of various rehabilitation techniques on repairing seismic damaged slab- column connections and improving the two-way shear strength of deficient connections. Three alternatives for rehabilitating slab-column connections
null Widianto +2 more
openaire +1 more source
Ductility of Reinforced Concrete Flat Slab‐Column Connections
Computer-Aided Civil and Infrastructure Engineering, 2005Abstract: The article presents experimental and analytical research on providing adequate ductility and rotational capacity to reinforced concrete slab‐column connections. Post peak‐load ductility of connections in reinforced concrete framed structures is essential for ensuring structural integrity and preventing local failure that may lead to ...
openaire +1 more source
Punching Shear Capacity of Interior SFRC Slab-Column Connections
Journal of Structural Engineering, 2012AbstractThe paper deals with the punching shear behavior and the capacity of interior steel fiber-reinforced concrete (SFRC) slab-column connections. In the experimental study, the effect of the amount of fibers on the punching shear resistance and cracking behavior of slabs was investigated on a total of 12 small-scale flat slabs of varying dimensions.
Long Nguyen-Minh +2 more
openaire +1 more source
Moment Transfer by Shear in Slab-Column Connections
ACI Structural Journal, 1996A bending moment M u transferred at a slab-column connection is resisted at the slab critical sections by flexure and shear. The ACI 318-89 Building Code 1 and the Canadian Standard CAN3-A23.3-M84 2 give an empirical equation for the fraction γ V of the moment M u to be transferred by shear at the slab critical section at d/2 from the column face.
openaire +1 more source