Results 131 to 140 of about 21,179 (236)

Double‐Sided Mechanical Interlocking Enables Soft‐Rigid Conductive Interfaces With a Record High Toughness for Flexible Electronics

open access: yesAdvanced Materials, EarlyView.
A double‐sided mechanical interlocking strategy is developed to create robust electrical contact between polymer electrode and metal interconnect. The fibrous structure enables formation of thread–hole adhesion, which only breaks under bulk failure and achieves a record high interfacial energy exceeding 730 J·m−2. This adhesion secures the integrity of
Gang Li   +6 more
wiley   +1 more source

E. coli Extracellular Matrix: A Tunable Composite With Hierarchical Structure

open access: yesAdvanced Materials, EarlyView.
The complex composite‐like mechanical behavior of E. coli biofilm matrix is the result of a synergic contribution of the rigid curli and swelling pEtN‐cellulose, and emerges from specific ratio and assembly conditions. The interactions between the two fibers govern biofilm hydration and characteristic wrinkling patterns, providing crucial insights for ...
Macarena Siri   +7 more
wiley   +1 more source

A Dual‐Bioresponsive and Programmable Microneedle Matrix as a Bioinspired Coupler for Orchestrating Diabetic Bone Regeneration

open access: yesAdvanced Materials, EarlyView.
This project developed a smart bandage‐like patch (a microneedle array) for repairing diabetic bone damage. It intelligently senses signals from infection and inflammation, then releases its medicines in a specific, timed sequence: first an antibacterial agent, then an anti‐inflammatory agent, and finally growth factors.
Yu Wang   +10 more
wiley   +1 more source

Nocturnal Intraocular Pressure Monitoring With a Soft Contact Lens Sensor for Glaucoma Management

open access: yesAdvanced Materials, EarlyView.
A soft contact lens sensor enables continuous, noninvasive monitoring of nocturnal intraocular pressure (IOP) under closed‐eye sleep conditions. By integrating a highly compliant inductive–capacitive circuit onto a commercial lens, the device achieves record sensitivity and stable performance.
Yumin Dai   +19 more
wiley   +1 more source

Regression Is All You Need for Medical Image Translation. [PDF]

open access: yesIEEE Trans Med Imaging
Rassmann S, Kugler D, Ewert C, Reuter M.
europepmc   +1 more source

BioEISense: A Microfluidic Platform for Real‐Time Monitoring of Staphylococcus aureus Biofilm Formation and the Efficacy of Antibiofilm Agents

open access: yesAdvanced Materials Interfaces, EarlyView.
BioEISense is a microfluidic device with integrated impedance sensors, for real‐time, label‐free monitoring of S. aureus biofilms. In this study, the biofilm culture conditions were optimized to support sensitive and reproducible detection of biofilm formation and eradication under dynamic flow‐through conditions. The system was also validated for both
Jéssica Amorim   +6 more
wiley   +1 more source

Home - About - Disclaimer - Privacy