Assessment of the Hydrogen Induced Stress Cracking Resistance of Precipitation Hardened Nickel-based Alloys Using the Slow Strain Rate Tensile Test Method – Review of a Three Years Test Program

Corrosion, 2019
Precipitation Hardened (PH) Ni-based alloys have proved to be sensitive to Hydrogen Induced Stress Cracking (HISC), and HISC related failures in the Oil and Gas industry have been experienced in the case of UNS N07718, UNS N07725 and UNS N07716.
C. Duret-Thual   +6 more
semanticscholar   +1 more source

Stress Corrosion Behavior of AISI 304 Stainless Steel in a Boiling 42% MgCl2 Solution under Cyclic Slow Strain Rate Technique

open access: yes, 1985
Stress corrosion cracking (SCC) behavior of AISI 304 stainless steel (SS) rod and plate specimens in boiling 42% MgCl2 was investigated using a monotonic and a cyclic slow strain rate technique (SSRT) in the crosshead speed (CHS) range from 6×10−5 to 1.5
T. Nakayama, M. Takano
semanticscholar   +2 more sources

Assessment of the Hydrogen Induced Stress Cracking Resistance of Precipitation Hardened Nickel-based Alloys Using the Slow Strain Rate Tensile Test Method: Influence of Microstructure

Corrosion, 2019
Within the framework of a Joint Industrial Project sponsored by several petroleum companies, the behavior of several Precipitation Hardened (PH) Ni-based alloys with respect to Hydrogen Induced Stress Cracking (HISC) resistance was studied, using the ...
I. Salvatori   +5 more
semanticscholar   +1 more source

Effect of Slow Strain Rates on the Hydrogen Migration and Different Crack Propagation Modes in Pipeline Steel

Steel Research International, 2023
The slow‐strain‐rate test (SSRT) is the most commonly used method for evaluating pipeline steel in service environments. However, to accurately assess the sensitivity of steel to hydrogen, it is necessary to investigate the effect of different strain ...
Zhixian Peng   +5 more
semanticscholar   +1 more source

Acoustic Emission Monitoring of Slow Strain Rate Tensile Tests of 304L Stainless Steel in Supercritical Water Environment

open access: yes, 2011
An experimental set-up has been developed to perform slow strain rate tensile (SSRT) tests on tubular 304L stainless steel (SS) specimens in supercritical water (SCW) environment (550oC, 250 bar).
K. Máthis   +3 more
semanticscholar   +2 more sources

Application of the slow strain rate test method to assess the tendency of corrosion-resistant steels and alloys to sulfide cracking

Industrial laboratory Diagnostics of materials
The results obtained after tests using the slow strain rate test method (SSRT) to determine the tendency to sulfide stress cracking (SSC) of corrosion-resistant steels of ferritic, austenitic, austenitic-ferritic and martensitic classes as well as ...
A. Khar’kov   +4 more
semanticscholar   +1 more source

Environmental Cracking Evaluation of Corrosion Resistant Alloys in H2S-CO2-Cl- Environment by Slow Strain Rate Tensile Test

Corrosion, 1989
A slow strain rate test (SSRT) is effective to survey materials selection for a hostile well such as deep sour gas. In order to use effectively data from different sources, it is necessary to make causes of error or variance clear and minimize data ...
A. Ikeda, M. Ueda, H. Tsuge
semanticscholar   +1 more source

Behavior of constitutive models from slow strain rate test of maraging 300 and 350 steels performed in several environmental conditions

International Journal of Fracture, 2022
R. Chales   +8 more
semanticscholar   +1 more source

Investigation of the Effect of pH on Stress Corrosion Cracking of API 5L X65 Steel by Impedance Spectroscopy and Slow Strain Rate Tensile Test

Journal of materials engineering and performance (Print), 2021
S. Hassanzadeh   +5 more