Results 271 to 280 of about 48,819 (306)
Some of the next articles are maybe not open access.
Research on Switching Power Supply Based on Soft Switching Technology
2020Aiming at the problem that it is difficult to realize zero voltage and zero current switching (ZVZCS) in the current switching power supply, the resonance energy of the lagging arm is insufficient. In this paper, with TMS320F2812 as the control core, the DC/DC part of the switching power supply is designed by using the PWM phase shift control full ...
Zhihong Zhang, Hong He
openaire +1 more source
Journal of Power Electronics, 2020
The soft-switching buck inverter, which is mainly applied to solve the contradictions between the switching frequency and the shoot-through problem along with the dead-time effect, is proposed in this paper. A detailed analysis of the relationship between the range of the duty ratio to realize soft-switching as well as the additional voltage stress and
Wei Xu, Xiaohua Wu, Feng Hong
openaire +1 more source
The soft-switching buck inverter, which is mainly applied to solve the contradictions between the switching frequency and the shoot-through problem along with the dead-time effect, is proposed in this paper. A detailed analysis of the relationship between the range of the duty ratio to realize soft-switching as well as the additional voltage stress and
Wei Xu, Xiaohua Wu, Feng Hong
openaire +1 more source
A Soft-Switching Double-Input Micro-Inverter
IEEE Transactions on Industrial Electronics, 2021In this article, a new high step-up soft-switched double-input micro-inverter is introduced, which is proper for low-power applications. This inverter is composed of a forward resonant inverter and two series boost converters that are coupled electrically and apply five switches.
Ehsan Karimi +2 more
openaire +1 more source
Soft-Switching Power Conversion
EPE Journal, 1993This paper presents a survey of research and development on resonant converter topologies for DC and AC applications.
J.B. Klaassens +2 more
openaire +1 more source
Soft switching of KY converter
2008 Twenty-Third Annual IEEE Applied Power Electronics Conference and Exposition, 2008In this paper, the soft switching technique is applied to the KY converter to upgrade the efficiency in the neighborhood of the rated load and hence enhance its capability in industrial applications. The details of the soft switching for the KY converter are illustrated along with some simulation and experimental results to verify the effectiveness of ...
K. I. Hwu, Y. T. Yau
openaire +1 more source
Design of Soft-Switched Inverter
Applied Mechanics and Materials, 2014In order to decrease the exhaust of the switch of inverter bridge arm, the auxiliary resonant net was imbed in the circuit structure which lead to cost ascension and credibility descend. This text discusses to design a DC/AC converter based on simplex single voltage source high frequency chain inversion technology, the output is 0.9KW/115V/400Hz.The ...
Lu Wang +3 more
openaire +1 more source
Soft-switching inverter for electrodynamicshaker
IEE Proceedings - Electric Power Applications, 1999The paper presents the design and implementation of a soft-switching inverter with zero voltage transition (ZVT) for shaker armature excitation, First, the circuit configuration and the operation principle of the proposed inverter are introduced in detail.
T.H. Chen, C.M. Liaw
openaire +1 more source
2015
Switch-mode power converters are used in a wide variety of applications. In most applications, it is desirable to design high-frequency switching power converters to increase their power density. However, the switching losses are increased by increasing the frequency. Moreover, large dv/dt and di/dt produce electromagnetic interference. To minimize the
openaire +1 more source
Switch-mode power converters are used in a wide variety of applications. In most applications, it is desirable to design high-frequency switching power converters to increase their power density. However, the switching losses are increased by increasing the frequency. Moreover, large dv/dt and di/dt produce electromagnetic interference. To minimize the
openaire +1 more source
Losses in soft-switched and hard-switched voltage inverters
2003 IEEE International Symposium on Industrial Electronics ( Cat. No.03TH8692), 2004This paper introduces an adequate loss model, based on the experimental results, which can be used to estimate the losses in hard-switched and soft-switched inverters. As an example and considering the use of IGBTs, it compares the losses produced by hard-switched, auxiliary resonant commutated pole (ARCP) and quasi-square-wave (QSW) inverters for ...
M.C. Cavalcanti +2 more
openaire +1 more source

