The voltage source converter‐based high voltage direct current transmission (VSC‐HVDC) is considered the most appropriate option to harness the maximum potential of renewable energy, particularly offshore wind. With improved reliability and functionality of the network, reduced conversion losses, and reduced cost, the VSC‐based multiterminal direct ...
Muhammad Ahmad +5 more
wiley +1 more source
The integration of distributed renewable energy resources in combination with advancements in power electronics make the application of multi‐terminal medium voltage DC grids a promising and flexible solution. Fast and selective protection concepts in combination with DC (disconnecting) switches for fault handling are required to ensure high ...
Maximilian Stumpe +3 more
wiley +1 more source
A novel thyristor‐based hybrid DC circuit breaker with short arcing capability
Abstract Multi‐terminal flexible high‐voltage direct current (HVDC) transmission and DC grid technology are developing rapidly. The hybrid DC circuit breaker (HCB) has broad application prospects in the field of HVDC transmission and DC power grid. Nevertheless, existing HCBs have one or more following blemishes: arc suppression scheme of mechanical ...
Guanlong Jia +4 more
wiley +1 more source
Metrology requirements of state‐of‐the‐art protection schemes for DC microgrids
Environmental incentives to combat climate change are providing the motivation to improve the energy efficiency of power distribution systems and integrate state‐of‐the‐art renewable technologies. Examples include wind/photovoltaic resources, energy storage systems, and electric vehicles integrated via efficient power electronic converters (PEC ...
Chunpeng Li +4 more
wiley +1 more source
The dc solid-state circuit breaker (SSCB) is commonly used to protect sensitive equipment and enhance system stability by quickly interrupting fault currents, thereby increasing overall safety.
Phanit Sok +3 more
doaj +1 more source
Research of simulation and experiment on arc characteristics of gas mechanical switch
Abstract An arc is the high‐temperature discharge plasma produced in the opening process of mechanical switches, which directly affects the breaking capability of a hybrid DC circuit breaker. According to the physical mechanism of an electric arc, the construction of an arc model for simulation analysis is an important technical means in the electrical
Cheng Jiang +7 more
wiley +1 more source
DC technologies constitute essential components within the scope of DC distribution networks. All DC networks confront inherent threats, such as DC short‐circuit faults, necessitating robust protective measures. Utilizing DC circuit breakers (DCCBs) emerges as a pivotal strategy for safeguarding these networks.
Sabah Daniar +2 more
wiley +1 more source
Evaluation of existing DC protection solutions on the performance of an active LVDC distribution network under different fault conditions [PDF]
Low Voltage Direct Current (LVDC) distribution is one of the new promising technologies that has been introduced for the integration of renewables and powering certain applications.
Burt, Graeme +3 more
core
Design of a Solid-State Circuit Breaker for a DC Grid-Based Vessel Power System [PDF]
Electric propulsion and integrated hybrid power systems can improve the energy efficiency and fuel consumption of different kinds of vessels. If the vessel power system is based on DC grid distribution, some benefits such as higher generator e ciency ...
Abad Biain, Gonzalo +2 more
core +1 more source
Protection Scheme based on Artificial Neural Network for Fault Detection and Classification in Low Voltage PV-Based DC Microgrid [PDF]
With the expansion of the DC distribution market, protection, and operational concerns for Direct Current (DC) Microgrids have increased. Different systems have been investigated for detecting, finding, and isolating defects utilising a variety of ...
Ramaprasanna Dalai, et al.
core +2 more sources