Results 51 to 60 of about 325 (124)
Self-Powered 380 V DC SiC Solid-State Circuit Breaker and Fault Current Limiter [PDF]
This paper presents a new ultrafast dc solid-state circuit breaker (SSCB) that uses a silicon carbide cascode as themain switching and limiting semiconductor and an isolated photovoltaic driver to control it.
Blanes, José Manuel +3 more
core +1 more source
A novel thyristor‐based hybrid DC circuit breaker with short arcing capability
Abstract Multi‐terminal flexible high‐voltage direct current (HVDC) transmission and DC grid technology are developing rapidly. The hybrid DC circuit breaker (HCB) has broad application prospects in the field of HVDC transmission and DC power grid. Nevertheless, existing HCBs have one or more following blemishes: arc suppression scheme of mechanical ...
Guanlong Jia +4 more
wiley +1 more source
Metrology requirements of state‐of‐the‐art protection schemes for DC microgrids
Environmental incentives to combat climate change are providing the motivation to improve the energy efficiency of power distribution systems and integrate state‐of‐the‐art renewable technologies. Examples include wind/photovoltaic resources, energy storage systems, and electric vehicles integrated via efficient power electronic converters (PEC ...
Chunpeng Li +4 more
wiley +1 more source
The dc solid-state circuit breaker (SSCB) is commonly used to protect sensitive equipment and enhance system stability by quickly interrupting fault currents, thereby increasing overall safety.
Phanit Sok +3 more
doaj +1 more source
Research of simulation and experiment on arc characteristics of gas mechanical switch
Abstract An arc is the high‐temperature discharge plasma produced in the opening process of mechanical switches, which directly affects the breaking capability of a hybrid DC circuit breaker. According to the physical mechanism of an electric arc, the construction of an arc model for simulation analysis is an important technical means in the electrical
Cheng Jiang +7 more
wiley +1 more source
Design of a Solid-State Circuit Breaker for a DC Grid-Based Vessel Power System [PDF]
Electric propulsion and integrated hybrid power systems can improve the energy efficiency and fuel consumption of different kinds of vessels. If the vessel power system is based on DC grid distribution, some benefits such as higher generator e ciency ...
Abad Biain, Gonzalo +2 more
core +1 more source
Protection Scheme based on Artificial Neural Network for Fault Detection and Classification in Low Voltage PV-Based DC Microgrid [PDF]
With the expansion of the DC distribution market, protection, and operational concerns for Direct Current (DC) Microgrids have increased. Different systems have been investigated for detecting, finding, and isolating defects utilising a variety of ...
Ramaprasanna Dalai, et al.
core +2 more sources
DC technologies constitute essential components within the scope of DC distribution networks. All DC networks confront inherent threats, such as DC short‐circuit faults, necessitating robust protective measures. Utilizing DC circuit breakers (DCCBs) emerges as a pivotal strategy for safeguarding these networks.
Sabah Daniar +2 more
wiley +1 more source
The DC Solid-State Circuit Breaker (SSCB) is usually used to prevent damage to sensitive equipment and ensure system stability by rapidly interrupting fault currents and improving safety.
Phanit Sok +2 more
doaj +1 more source
Impact of key design constraints on fault management strategies for distributed electrical propulsion aircraft [PDF]
Electrically driven distributed propulsion has been presented as a possible solution to reduce aircraft noise and emissions, despite increasing global levels of air travel.
Flynn, Marie-Claire +4 more