Results 21 to 30 of about 36,401 (248)
Pudendal Cortical Somatosensory Evoked Potentials
To determine normal reference latencies pudendal cortical somatosensory evoked potentials were evaluated in 20 healthy volunteers. The dorsal nerve of the penis or clitoris was stimulated electrically and the cortical response was recorded from the CZ-2 point (2 cm. behind the central vertex).
Opsomer, Reinier-Jacques +3 more
openaire +3 more sources
The interaction of auditory evoked potential (AEP) and somatosensory evoked potential (SEP) which is evoked by electrical stimulation of acupuncture points in guinea pig was observed.
周庆辉 +5 more
doaj +2 more sources
Intra-Operative Somatosensory-Evoked Potential Monitoring
Purpose. To evaluate the usefulness of intra-operative somatosensory-evoked potentials (SSEPs) in monitoring spinal cord status via the posterior tibial nerve. Methods.
AS Chandanwale, AA Ramteke, S Barhate
doaj +1 more source
Dense tactile streams from across the humanoid body converge on collide in a central wiring and data bottleneck. By relocating computation closer to and then into the skin itself, near‐ and in‐sensor architectures, together with neuromorphic computing, chart a path toward perception‐native electronic skin, in which the conversion of stimulus into ...
Mijin Kim +6 more
wiley +1 more source
Background Somatosensory evoked potentials may add substantial prognostic value in patients with acute ischemic stroke and contribute to the selection of patients who may benefit from revascularization therapies beyond the accepted therapeutic time ...
Alicia Martinez‐Piñeiro +19 more
doaj +1 more source
Organoid Brain‐Machine‐Interface Devices for Central Nervous System Repair
We envision organoid brain‐machine‐interface (Organoid‐BMI) devices as new biohybrid bidirectional communication pathways to connect the human CNS and the external world for personalized CNS repair and regeneration. ABSTRACT Central nervous system (CNS) repair and regeneration suffer from tremendous clinical challenges due to current limitations in ...
Yantao Xing +10 more
wiley +1 more source
Osseoperceptive EMG Feedback Improves Grasp Force Control in Myoelectric Prosthetic Hands
Osseoperception is explored as a non‐invasive pathway for delivering sensory feedback in myoelectric prosthetic control. By encoding the user's electromyographic (EMG) signal through bone‐conducted stimulation, this approach enables predictive grasp force regulation.
Cristian Felipe Blanco‐Diaz +2 more
wiley +1 more source
Extrusion‐based 3D printing of silicones and discrete electronic components are combined to create cortical implants for rodents that integrate thermal neuromodulation and electrical recording. Linked to an autonomous auxiliary driver unit, the system enables rapid, stable and localized hypothermia alongside ECoG recording.
Spencer Ryan Moore +6 more
wiley +1 more source
Neuronal activation leads to astrocytic transient volume changes, activating transient receptor potential ankyrin 1 (TRPA1) channels, leading to Ca2+ influx. Activation of TRPA1 causes the release of D‐serine through BEST1. Finally, the augmented extracellular levels of D‐serine boost neuronal activity by binding GluN1‐containing NMDARs, leading to CBV
Kayoung Han +11 more
wiley +1 more source
Quantifying the effect of isoflurane and nitrous oxide on somatosensory-evoked potentials
Anaesthetic techniques may have a significant effect on intraoperative-evoked potentials (EP). The present study is designed to compare Propofol anaesthesia with Isoflurane (with or without nitrous oxide) during intraoperative somatosensory-evoked ...
Usha Devadoss, S Babu, V T Cherian
doaj +1 more source

