Results 271 to 280 of about 1,549,598 (319)

Realization of highly asymmetric hydrogenated graphene in the van der Waals confined space. [PDF]

open access: yesNatl Sci Rev
Huang X   +9 more
europepmc   +1 more source

Improving dose delivery in non‐coplanar cranial SRS: Stereoscopic x‐ray‐guided mitigation of table walkout errors

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Purpose Linear accelerator (LINAC)‐based single‐isocenter multi‐target (SIMT) treatment has streamlined the cranial stereotactic radiosurgery (SRS) workflow. Though efficient, SIMT delivery adds additional challenges that should be considered, including increased sensitivity to rotational errors for off‐isocenter targets.
Yohan A. Walter   +4 more
wiley   +1 more source

One-degree-of-freedom flat-foldable thick-panel origami-kirigami structures: modular arrays and closed polyhedra. [PDF]

open access: yesCommun Eng
Zhao C   +10 more
europepmc   +1 more source

Log file‐based quality assurance method for respiratory gating system

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Background As medical linear accelerator technology advances, enabling higher dose rate deliveries, hypofractionation regimens has increased. This necessitates respiratory gating systems that synchronize radiation delivery with tumor position, requiring simple rigorous quality assurance (QA) to ensure treatment accuracy and patient safety ...
Wonjoong Cheon   +7 more
wiley   +1 more source

Machine stability and dosimetry for ultra‐high dose rate FLASH radiotherapy human clinical protocol

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Background The FLASH effect, induced by ultra‐high dose rate (UHDR) irradiations, offers the potential to spare normal tissue while effectively treating tumors. It is important to achieve precise and accurate dose delivery and to establish reliable detector systems, particularly for clinical trials needed to help the clinical transfer of FLASH‐
Patrik Gonçalves Jorge   +9 more
wiley   +1 more source

An investigation into the feasibility and efficacy of stereotactic radiosurgery for 1–3 cm single brain lesions on the ring‐mounted Halcyon LINAC

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose An evaluation of the accuracy, safety, and efficiency of the Halcyon ring delivery system (RDS) for stereotactic radiosurgery (SRS) treatment to relatively small (1–3 cm) brain lesions. Methods After completing the extensive in‐house quality assurance checks including Winston–Lutz test and independent dose verification via MD Anderson ...
Kate Hazelwood   +5 more
wiley   +1 more source

Unsupervised non‐small cell lung cancer tumor segmentation using cycled generative adversarial network with similarity‐based discriminator

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Background Tumor segmentation is crucial for lung disease diagnosis and treatment. Most existing deep learning‐based automatic segmentation methods rely on manually annotated data for network training. Purpose This study aims to develop an unsupervised tumor segmentation network smic‐GAN by using a similarity‐driven generative adversarial ...
Chengyijue Fang   +2 more
wiley   +1 more source

Free-space high-Q nanophotonics. [PDF]

open access: yesLight Sci Appl
Yu J, Yao W, Qiu M, Li Q.
europepmc   +1 more source

Home - About - Disclaimer - Privacy