The impact of the inclination angle of perforated screen facade on daylight performance in the tropics [PDF]
Daylighting is one of the fundamental aspects of green building principles. Utilizing daylighting in a building offers numerous benefits, including energy efficiency, enhanced comfort, improved workplace productivity, better health, and increased ...
Feny Elsiana, Danny Santoso Mintorogo
doaj +3 more sources
Spatio-Temporal Visualisation of Reflections from Building Integrated Photovoltaics
With the increasing adoption of building integrated photovoltaics (BIPV), concerns arise about potential glare. While recommended criteria to assess glare exist, it is challenging to apply these in the spatial and temporal domains and communicate the ...
Roland Schregle +2 more
doaj +1 more source
Annual Daylight Performance of Perforated Screen Facade in Loft Office in the Tropics
Implementing daylighting in office buildings offers energy savings and psychological and physiological benefits for occupants. One type of office currently developing in Indonesia is the loft office, which is characterized by a mezzanine floor, a high ...
Feny Elsiana, Danny S. Mintorogo
doaj +1 more source
Design Adjustments For Daylighting and Visual Comfort in a Classroom with Conventional Shadings
This paper evaluates how design adjustments applied to roller shades and louvres (namely the height of the shadings head and the angles of the louvre slats) can improve their annual and spatial effectiveness to provide autonomous daylight levels, reduce ...
Doris A. Chi
doaj +1 more source
Daylight Enhancement Strategies Through Roof for Heritage Buildings
Enhancing daylighting in heritage buildings is a complex challenge that requires a delicate balance between preserving architectural integrity and improving visual comfort.
Nurefşan Sönmez +2 more
doaj +1 more source
Influence of macular pigment on the sensitivity to discomfort glare from daylight. [PDF]
Jain S +5 more
europepmc +1 more source
Five-Year Clinical Outcomes of Low-Add-Power Segmented Rotationally Asymmetrical Intraocular Lens. [PDF]
Oshika T, Arai H, Inoue Y, Fujita Y.
europepmc +1 more source
Surgical outcome comparisons of multifocal IOLs of Lentis Comfort LS-313 MF15 and Tecnis Eyhance DIB00V. [PDF]
Sugawara K +6 more
europepmc +1 more source
Simple mathematical models to link climate-based daylight metrics with daylight factor metrics and daylighting design implications. [PDF]
Li S, Li DHW, Chen W, Lou S, Tsang EKW.
europepmc +1 more source
Fundus autofluorescence imaging using red excitation light. [PDF]
Birtel J +5 more
europepmc +1 more source

