Results 221 to 230 of about 1,155,432 (434)

Geometric and dosimetric evaluation of a commercial AI auto‐contouring tool on multiple anatomical sites in CT scans

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Current radiotherapy practices rely on manual contouring of CT scans, which is time‐consuming, prone to variability, and requires highly trained experts. There is a need for more efficient and consistent contouring methods. This study evaluated the performance of the Varian Ethos AI auto‐contouring tool to assess its potential integration into
Robert N. Finnegan   +6 more
wiley   +1 more source

Dosimetric effect of silicone‐based gel on skin surface during volumetric modulated arc therapy for breast cancer

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose This study aims to quantify and compare the dosimetric effects of varying thicknesses of StrataXRT, a silicone‐based gel, and other topical agents on the skin surface during volumetric modulated arc therapy (VMAT) for breast cancer.
Tenyoh Suzuki   +13 more
wiley   +1 more source

Artificial intelligence in radiation oncology: A specialty-wide disruptive transformation?

open access: yesRadiotherapy and Oncology, 2018
Reid F Thompson   +12 more
semanticscholar   +1 more source

An alternative theory of the plant size distribution with an application to trade [PDF]

open access: yes
There is wide variation in the sizes of manufacturing plants, even within the most narrowly defined industry classifications used by statistical agencies. Standard theories attribute all such size differences to productivity differences.
John J. Stevens, Thomas J. Holmes
core  

Diagnostic image‐based treatment planning for online adaptive ultra‐hypofractionated prostate cancer radiotherapy with MR‐Linac

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose A new workflow was investigated for Elekta Unity MR‐Linac by removing the computed tomography (CT)‐simulation step and using diagnostic CT (DCT) for reference plan generation. Materials and methods Ten patients with ultra‐hypofractionated prostate cancer treated with magnetic resonance imaging (MRI)‐guided adaptive radiotherapy were ...
Yuan Xu   +5 more
wiley   +1 more source

BreastWatch: A Varian Eclipse script tool for Community‐Based automatic evaluation of breast treatment plans

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose This work introduces BreastWatch, a Varian Eclipse script tool designed to help medical physicists, dosimetrists, and radiation oncologists easily inspect and improve External Beam Breast Treatment (EBBT) plans using automatic evaluation of protocol dose‐constraints enhanced by a Community‐Based approach.
Stefano Agostinelli   +8 more
wiley   +1 more source

Home - About - Disclaimer - Privacy