Results 131 to 140 of about 85,035 (307)
Cell therapies typically rely on cold‐chain logistics and cryopreservation, limiting access and compromising cell quality. Here, a dual‐chamber device separates an oxygen‐supplying chamber from a hyaluronic acid cargo chamber, sustaining oxygen delivery for over 70 h and enabling ambient‐temperature shipment.
Daniel A. Domingo‐Lopez +9 more
wiley +1 more source
Fully Polarimetric SAR Image Filtering by Combining Block Matching and Lee Filter
Speckle filtering is a key preprocessing approach for the applications of polarimetric synthetic aperture radar (PolSAR) data. Most current PolSAR filtering algorithms can hardly get good balance in suppressing speckle and retaining image details.
Guisheng Zhao, Shengyuan Zhu, Yinglei Wu
doaj +1 more source
Phase errors in speckle reduced laser fringe projection
When measuring 3D-shape with triangulation and projected interference fringes it is of interest to reduce the phase error in the fringe pattern. A study has been carried out concerning parameters that will affect the phase error and an analytical ...
P. Gren +7 more
core +1 more source
An Adaptive Inhibitory WSe2 Transistor for Retinomorphic In‐Sensor Image Processing
Conventional retinomorphic devices typically require deliberate gate‐bias tuning for each illumination condition. In this paper, we demonstrate an adaptive inhibitory WSe2 transistor that uses photo‐induced regime shift between the subthreshold and accumulation modes to achieve decision‐free, intensity‐adaptive image processing within a single pixel ...
Juhwan Baek +12 more
wiley +1 more source
Interferometry often serves as an essential building block of wavefront shaping systems to obtain optimal wavefront solutions. In this tutorial, we provide a Monte Carlo simulation tool to calculate the accuracy of interferometric measurements and its ...
Chunghyeong Lee +3 more
doaj +1 more source
Comparison between process simulation and deformation measured by defocused speckle photography
Defocused laser speckle photography is used as a tool to measure the heat responses in a titanium component during laser heating. The evolution of the response is compared with a set of preprocessed Finite Element Simulations of the corresponding process
Sjödahl, Mikael, +6 more
core +1 more source
A removable sacrificial polymer layer engineers the thermal boundary condition during nanosecond laser ablation of PET, suppressing heat‐affected‐zone formation without relying on costly ultrafast lasers. This strategy enables deep, high‐aspect‐ratio trenches with no detectable heat‐affected zone, templating silver‐filled mesh electrodes with record ...
Mehdi Zarei +3 more
wiley +1 more source
A degradable, skin‐conformal bioelectronic patch combines a starch‐dominated nanocomposite conductor with a gelatin substrate to enable sensitive strain sensing, high‐fidelity electrocardiography, electromyography, electrooculography, and machine‐learning‐assisted gesture control.
Ming Dong +10 more
wiley +1 more source
3D‐Printed Gradient Shape‐Memory Strain Sensors With Rewritable Gauge Factors
A 3D‐printed shape‐memory strain sensor combines thermomechanical programming with gradient architectural design. Preset strain rewrites the gauge factor (GF), while the gradient geometry amplifies the response through strain redistribution. Reprogrammable sensitivity enables the same sensor to detect weak pulse signals and monitor large‐amplitude ...
Xuan Zhang +10 more
wiley +1 more source
Analysis of Despeckling Filters Using Ratio Images and Divergence Measurement
This paper presents an analysis of different despeckling filters applied on both synthetically corrupted optical images and actual Synthetic Aperture Radar (SAR) images. Several authors use optical images as ground truth and then the images are corrupted
Luis Gómez +3 more
doaj +1 more source

