Results 11 to 20 of about 103,858 (241)
This paper reviews the composition, development, and operation mechanism of domestic and foreign fire protection technical regulations and standards. Considering the development and problems of China's fire protection standard system and fire protection ...
Xuan Sun, Na Cai, Wei Zhang
doaj +1 more source
Multiple spurious operations (MSOs) mean multiple fire induced circuit faults causing an undesired operation of one or more systems or components. The Nuclear Energy Institute (NEI) of the United States published NEI 00-01 as guidelines for solving MSOs.
Jaehwan Kim +3 more
doaj +1 more source
Linear smoke detectors in fire protection [PDF]
Smoke detectors generally present the most frequently used fire detectors. These detectors have great appliance because smoke presents the consequence of many fires.
Jevtić Radoje B.
doaj +1 more source
In this paper the author presents the results of experiments with the three steel grades under thermal conditions of the standard fire with account of the change of stress in steel samples, similar to changes of stress in the reinforcement, resulting ...
Zoja Bednarek
doaj +1 more source
In a situation where a fire occurs either in a tunnel with a burning vehicle carrying petroleum products, at an offshore platform, or at an oil and gas asset to be protected, such a case is commonly described using a hydrocarbon fire curve. Therefore, it
Marina Gravit +3 more
doaj +1 more source
Inferring target reliability index of reinforced concrete beams in a standard fire situation according to Brazilian standards [PDF]
Since there is no consensus in the literature on the target reliability index values of reinforced concrete structures in a fire situation, this article aims to present a methodology for inferring the implicit target reliability index range for ...
Rodrigo Maffessoni Pires +1 more
doaj +1 more source
Fire-Resistance Testing Procedures for Construction Elements—A Review
Fire accidents are a significant risk to human life and civil infrastructure. As a countermeasure, the regulatory bodies of different countries have established standards for evaluating the performance of construction elements during fire exposure.
Shashikant Chaturvedi +5 more
doaj +1 more source
Fireproof suspended ceilings with high fire resistance limits
Suspended ceiling is an effective way to fire protection of horizontal structures with steel beams due to its lightness, reliability and functionality. Three designs of fireproof suspended ceiling with silicate plates on cement binder are considered.
Marina Gravit +3 more
doaj +1 more source
Thermal Characteristics of Epoxy Fire-Retardant Coatings under Different Fire Regimes
Different systems of fire protection coatings are used to protect the metal structures of stories and trestles at oil and gas facilities from low (when filling cryogenic liquids) and high temperatures (in case of the possible development of a hydrocarbon
Marina Gravit +2 more
doaj +1 more source
A Review of the Structural Fire Performance Testing Methods for Beam-to-Column Connections
The structural fire performance tests for beam-to-column connections are critical in determining their fire performance at high temperatures. The current standard fire testing methods provide the procedures for establishing the fire resistance of each ...
Noor Azim Mohd. Radzi +3 more
doaj +1 more source