Results 31 to 40 of about 904 (182)

Optimal Control of VSC for STATCOM Applications [PDF]

open access: yesIFAC Proceedings Volumes, 2012
Abstract In this work, a voltage source converter (VSC) is configured to perform STATCOM tasks and generate reactive power. An optimal H ∞ controller has been successfully implemented including an anti-windup compensator. Data from an experimental test bench is provided and compared with simulation results showing good accuracy level.
Bianchi, Fernando Daniel   +2 more
openaire   +2 more sources

Series Connection of LCC and Full Bridge MMC With DC Fault Ride‐Through Capability for Lightweight HVDC Transmission

open access: yesEngineering Reports, Volume 8, Issue 4, April 2026.
In this work, we investigate a lightweight HVDC converter topology that combines the strengths of line‐commutated converters (LCC) and full‐bridge modular multilevel converters (MMC) to address the high cost and large footprint of conventional HVDC stations.
Yang Wang   +7 more
wiley   +1 more source

Machine Learning and Artificial Intelligence Techniques for Intelligent Control and Forecasting in Energy Storage‐Based Power Systems

open access: yesEnergy Science &Engineering, Volume 14, Issue 4, Page 2318-2344, April 2026.
A new energy paradigm assisted by AI. ABSTRACT The tremendous penetration of renewable energy sources and the integration of power electronics components increase the complexity of the operation and power system control. The advancements in Artificial Intelligence and machine learning have demonstrated proficiency in processing tasks requiring ...
Balasundaram Bharaneedharan   +4 more
wiley   +1 more source

Enhancement of a Power System Transient Stability Using Static Synchronous Compensator STATCOM [PDF]

open access: yesEngineering and Technology Journal, 2013
In modern power system utilities, increased power demand often lead to the situation where the system no longer remains in secure operating region. Flexible AC Transmission Systems (FACTS) controllers can play an important roll in power system security ...
Naseer M. Yasin, Mustafa M. Al-Eedany
doaj   +1 more source

Mechanism and Control Analysis of Synchronous Frequency Resonance in Distributed Power Generation System Connected to Grid

open access: yesEnergy Science &Engineering, Volume 14, Issue 4, Page 2263-2276, April 2026.
Small‐signal modeling reveals that insufficient system damping positions conjugate poles near the imaginary axis, fundamentally explaining the SFR mechanism. A virtual resistance control is consequently proposed to damp the resonance and effectively suppress SFR, which is validated through Hardware‐in‐the‐Loop experiments.
Yujie Gu   +3 more
wiley   +1 more source

Multiterminal High‐Voltage Direct Current Projects: A Comprehensive Assessment and Future Prospects

open access: yesHigh Voltage, Volume 11, Issue 2, Page 317-344, April 2026.
ABSTRACT Multiterminal high‐voltage direct current (MT‐HVDC) systems are an important part of modern power systems, addressing the need for bulk power delivery and efficient renewable energy integration. This paper provides a comprehensive overview of recent advances in MT‐HVDC technology, including launched projects and ongoing initiatives.
Mohammad Hossein Mousavi   +3 more
wiley   +1 more source

A New Technique to Supply Fast Varying Reactive Power Using a STATCOM

open access: yesEletrônica de Potência, 2005
This paper proposes a new technique to compensate fast oscillating reactive power using a multipulse STATCOM. It is shown that the oscillating reactive power can be controlled in a simple way by maintaining the STATCOM dc voltage constant.
Tatiana Mariano Lessa de Assis   +3 more
doaj   +1 more source

Modeling and Simulation of Common Mode Voltage in a Three-Phase Delta Connection STATCOM with Parasitic Capacitors [PDF]

open access: yesIranian Journal of Electrical and Electronic Engineering, 2023
In this paper, parasitic capacitors and common mode voltage (CMV) are modeled in a delta connection multilevel cascaded STATCOM. In high frequency and high voltage applications the parasitic capacitors play important role in common mode voltages. In this
S. Shabani, M. Asadi, A. Zakipour
doaj  

Investigation of the Impact of XLPE Cable Ageing on Impedance Mismatch Characteristics and Unbalanced Behaviour in Hybrid Operation Systems

open access: yesHigh Voltage, Volume 11, Issue 2, Page 544-555, April 2026.
ABSTRACT In the Hainan–Guangdong interconnection project, oil leakage in oil‐filled cables required replacing the faulty core with a single core from a three‐core cross‐linked polyethylene (XLPE) cable, leading to mixed operation of XLPE and oil‐filled cables.
Liang Zou   +4 more
wiley   +1 more source

Use of FACTS devices in Mitigating Sub Synchronous Resonance

open access: yesAdvances in Electrical and Electronic Engineering, 2020
This study evaluates the use of Flexible Alternating Current Transmission System (FACTS) devices in mitigating Subsynchronous Resonance (SSR). SSR is defined as a condition wherein an electrical network exchanges energy with a turbine generator at one or
Mohammed Redha Qader
doaj   +1 more source

Home - About - Disclaimer - Privacy