Results 61 to 70 of about 908 (183)
Power quality is one of the important issues in wind energy systems as in all renewable energy systems. Reactive component of current in distribution systems causes negative effects on the network, including power loses, voltage drop, and reduced line ...
YANMAZ, K., ALTAS, I. H., MENGI, O. O.
doaj +1 more source
1) The typical operational risks and coupling characteristics of the AC/DC hybrid power grid are analyzed in detail. 2) A bi‐Level topology optimization method is designed for HVDC systems embedded in dense AC grids. 3) Considering engineering standards of both security and economy, multi‐dimensional security and stability constraints are incorporated ...
Mingxin Yan +5 more
wiley +1 more source
Enhanced critic‐only DQN with smoothing enables continuous SVC control for damping inter‐area oscillations. The state selection via participation and residue analysis captures critical key modes. Orthogonal array efficiently tunes hyperparameters with low cost.
Gunawan Dewantoro +3 more
wiley +1 more source
STATCOM: A Review on Different Configurations and Topologies [PDF]
Synchronous static compensators STATCOMs have been presented as a member of flexible alternating current transmission systems devices family in both distribution and transmission levels, namely distribution STATCOM and transmission STATCOM, respectively.
openaire +2 more sources
This paper builds an admittance model for a DFIG‐STATCOM parallel system. Based on the system, the paper provides a method to optimise the control of the STATCOM, which aims to increase the performance of the system during symmetrical faults .
Wenhao Du +5 more
wiley +1 more source
To address DC‐side voltage imbalance in star‐connected cascaded H‐bridge STATCOMs under unbalanced grids, a hybrid‐frequency power loop is introduced to enable interphase power transfer. A hybrid‐frequency PWM (HFPWM) method based on voltage vector superposition is proposed, which maintains superior output characteristics for the intermediate‐frequency
Zhendong Ji +4 more
wiley +1 more source
Influence of LCL Output Filter Parameter Changing on D-STATCOM Compensation Characteristics
Aim at the problem of D-STATCOM output containing plenty of switching ripple, LCL filter was designed. Influence of LCL filter parameters on the compensation characteristic of D-STATCOM was studied. Considering the compensation capacity of the D-STATCOM,
ZHANG Xingru
doaj
Modeling and Control Research of Fractional-Order Cascaded H-Bridge Multilevel STATCOM
This paper introduces fractional-order capacitors and fractional-order inductors into the conventional integer-order cascaded H-bridge multilevel static compensator (ICHM-STATCOM), thereby constructing the main circuit of the fractional-order cascaded H ...
Junhua Xu +5 more
doaj +1 more source
Design of a STATCOM Controller
The paper introduced working principle and control method of STATCOM and proposed a design scheme of a STATCOM controller. It also gave some problems and corresponding solutions including communication between the master controller and the slave one, jitter elimination in process of data transceiving of displaying CPLD, short circuit in bridges of IGBT
LIU Rao-long, MA Xiao-ping, ZHANG Ke
openaire +1 more source
Research of Chain Circuit STATCOM Based on CPS-SPWM Modulatio
In view of problem that nonlinear and impact load inject plenty of reactive power and harmonic wave into coal mine power grid, the paper researched chain circuit STATCOM based on CPS-SPWM modulation.
ZHAO Qiang, WANG Jia-jun
doaj

