Static Loading Tests of Composite Beams

2021
Short-term static loading tests of composite beams have been performed using a breaking machine in the Civil Engineering Faculty laboratories at the Technical University of Kosice. On the beams loaded with hydraulic presses, deflections and strains (relative deformations) in their steel and concrete regions have been measured, and the widths of cracks ...
Vincent Kvočák, Daniel Dubecký
openaire   +1 more source

Static pile load test inversion

2019
This paper presents an inversion scheme to estimate the load distribution along the pile shaft using data from static pile load test. The input data consist of load at the pile head and the corresponding movement. A forward model consisting of a t-z model is combined with a Genetic Algorithm (GA) in this inversion scheme.
Potty, Gopu R.   +3 more
openaire   +2 more sources

M256 Static Load Test

1993
Abstract : A series of static load experiments was conducted on the M256 gun system to determine if clearances existed between its various components and, if so, where. In particular, it was desired to ascertain whether the gun tube and recoil mechanism act as a single unit or if clearances that exist between their primary parts allow the gun tube to ...
Joe Thiravong   +2 more
openaire   +1 more source

Axial Pile Loading Test—Part 1: Static Loading

Geotechnical Testing Journal, 1985
Abstract The International Society of Soil Mechanics and Foundation Engineering established a technical committee to develop manuals for field and laboratory geotechnical tests. As one of these, recommendations on axial pile loading tests are presented to the profession resulting from four years of worldwide discussion among piling ...
openaire   +1 more source

Pile load transfer from static load test inversion

DFI Journal - The Journal of the Deep Foundations Institute, 2016
This paper presents an inversion scheme to estimate the distribution of load in a deep foundation from the load–movement curve measured at the head. The method may be useful in situations where static load tests have been performed on test piles that are not instrumented with strain gages or telltales, or the instrumentation data are unreliable.
openaire   +2 more sources

Optimum Jack Loads for Static and Fatigue Tests

Journal of Aircraft, 1995
An automated procedure used at the Northrop Grumman Corporation to determine the jack loads for static and fatigue structural tests is described. The procedure includes a recently developed method to automatically compute jack loads that satisfy jack-capacity and jack-direction constraints, while providing a best fit to known internal moment, shear ...
Fred Austin   +2 more
openaire   +1 more source

Static Plate Loading Tests on Overconsolidated Clay

Journal of the Geotechnical Engineering Division, 1982
Three in situ static plate loading tests carried out on a medium stiff, overconsolidated clay deposit are described and interpreted. In addition to the plate loading test results, the results from undrained static laboratory tests on Haga clay are also presented.
Knut H. Andersen, Per Stenhamar
openaire   +1 more source

BI-DIRECTIONAL STATIC LOAD TESTING

GEO-EXPO
A full-scale static load testing program can optimise many of the requirements in terms of costs and remove uncertainties. The bi-directional load testing method, by eliminating the reaction structures of the traditional top-down testing methodology, opens up unseen possibilities of the testing program in the most efficient, safe, and cost-effective ...
openaire   +1 more source

Batter Pile Static Load Test and Analysis

Applied Mechanics and Materials, 2012
This paper through the test results and theoretical calculation of the batter pile static load, analysis of the actual stress state of cables, and according to the test results to determine the level of the foundation soil resistance coefficient ratio and allow level a transplant.
Li Lan Zhang, Yao Dong Wu
openaire   +1 more source

Static Load Test of Frame-Structure Slab

Advanced Materials Research, 2013
Floor slab static load test is a important method to judge the performance and carrying capacity of the slab. This paper, with the background of a factory frame-structure slab, introduced the testing scheme, the details of the testing process as well as the test results. The testing cases provide a useful reference for the same type of project.