Results 51 to 60 of about 584,580 (206)
Limitations of cyclic pile load tests by kentledge system in soft clay soil
The paper describes the inadequacies of cycled head-down load tests on two barrettes and one bored pile installed in soft clay soil region in Binh Thanh district, and district 7, Ho Chi Minh City, Vietnam, respectively.
Lan Vu Hoang BACH, Dan V. TRAN
doaj
Behaviour of reinforced concrete beam under dynamic loading / Md Rasul Mohamad Nor [PDF]
The study of reinforced concrete beam behaviour under dynamic loading as well as static loading with respect to the serviceability and ultimate limits is undertaken A total of four (4) beams with minimum strength of 60 N/mm2 casted, Each beams underwent ...
Mohamad Nor, Md Rasul
core
Structural characterization of a first-generation articulated-truss joint for space crane application [PDF]
A first-generation space crane articulated-truss joint was statically and dynamically characterized in a configuration that approximated an operational environment.
Laufer, Joseph B. +4 more
core +1 more source
THE STATIC LOADING TESTS OF SPRINKLER PIPING
A series of experimental study to investigate the bending strength and flexibility of steel sprinkler pipe through static loading tests, are carried out. These pipe systems don’t adopt flexible joints. To investigate the aging effect, aged pipes are tested and compared with new pipes.
Erika SHIZU +4 more
openaire +2 more sources
Optimal economic and emission dispatch of photovoltaic integrated power system using firefly algorithm [PDF]
The main purpose of Economic Load Dispatch (ELD) is to determine the optimal output of generating units to meet the power demand at lowest possible cost and subjected to the operational constraints. Various ELD optimization methods have been developed in
Muhamad Salim, Muhamad Solahuddin
core
Calculation of Pile Side Friction by Multiparameter Statistical Analysis
In this paper, a static load test and a multiparameter statistical analysis method are used to study the value of pile side friction in different soil layers in a loess region.
Zhijun Zhou +4 more
doaj +1 more source
DC-10 composite vertical stabilizer ground test program [PDF]
A review of the structural configuration and ground test program is presented. Particular emphasis is placed on the testing of a full-scale stub box test subcomponent and full span ground test unit.
Palmer, J. M., Jr. +2 more
core +1 more source
There are many analysis methods to determine the ultimate bearing capacity of single pile by using the load-settlement curve obtained from the static load test, but so far, reasonable and theoretical calculation method to solve the ultimate bearing ...
Jibao YANG
doaj +1 more source
Development and test of advanced composite components. Center Directors discretionary fund program [PDF]
This report describes the design, analysis, fabrication, and test of a complex bathtub fitting. Graphite fibers in an epoxy matrix were utilized in manufacturing of 11 components representing four different design and layup concepts.
Engler, E. +7 more
core +1 more source
Seismic qualification of directional valve [PDF]
Seismic qualification tests on pneumatically operated directional valve were carried out in the shake table facility in Structural Integrity Division. Determination of the fundamental frequency for directional valve was carried out through exploratory ...
Brahma, KK
core

