Results 61 to 70 of about 9,596 (201)
An Eigenstructure Assignment for a Static Synchronous Compensator [PDF]
Problem statement: Power flow through an AC transmission line is influenced by three basic electrical parameters, which are line impedance, magnitudes and phase-shift angle between the sending and receiving voltages. Therefore, the change in any of the three basic parameters means a change in the power flow through the transmission line.
openaire +1 more source
The full body safety harness is a key part of an active fall arrest system. The harness serves two purposes, first, distributing fall forces safely across a worker's body in the event of a free fall, and second, providing freedom of movement sufficient ...
Che Senu, Nur Syazana +2 more
core
In ensuring sustainable power delivery under rapid growth in demand, modern power grids are characterized by advanced solutions such as flexible alternating current transmission systems and distributed generation.
Ahmad Abubakar Sadiq +4 more
doaj +1 more source
Kehilangan sinkronisasi menyebabkan generator tidak dalam keadaan steady state sehingga menyebabkan ketidakstabilan sistem. Dalam makalah ini, metode Nyquist digunakan untuk menentukan kestabilan transien pada generator sinkron menggunakan kurva Nyquist.
Mohammad Noor Hidayat +2 more
doaj +1 more source
This paper proposes a new control strategy based on multimodel linear optimization control (MMLOC) to damp power system low-frequency oscillations (LFO) faster.
Elahe Pagard +2 more
doaj +1 more source
Sensor & instrumentation system : series 2 [PDF]
This book is an introduction to a number of the topics in sensor and instrumentation systems. Many of the topics describe the design experiments and system measurement especially in sensor applications.
core
Design and Realization of Distribution Static Synchronous Compensator
According to the engineering requirement of power distribution network reactive power compensation, the paper presents a software and hardware design method of the STATCOM based on DSP. In order to stabilize the PCC voltage around a prescribed value in the direct current control mode, the three-level converter of three phase bridge of the equipment in ...
Feng Chen, Linsuo Zeng
openaire +2 more sources
Recently, the control of voltage instability through appropriate power factor correction programmes has become a necessity in power systems due to recurring blackouts and cascading outages that interrupt the smooth supply of electricity to customers.
Akinuli Abimbola, Anthony +5 more
openaire +2 more sources
Unbalanced voltage and harmonics are major challenges in a microgrid. Single- and two-phase loads and short circuit can make unbalanced voltage. Besides, nonlinear loads create harmonic components in the grid.
Ehsan Akbari, Abbas Zare Ghaleh Seyyedi
doaj +1 more source
Assesment and Analyze Hybride Control System in Distribution Static Synchronous Compensator Based Current Source Converter [PDF]
With the rapid technology advancement in control processes, electric utilities are experiencing more demanding requirements on the power quality from the large industrial power consumers. For achieved this purpose use of FACTS devices.
Seyed Mohammad Ali Zanjani +2 more
doaj