Integrity of VVER steam generator tubes

Theoretical and Applied Fracture Mechanics, 1995
Abstract The eddy-current inspection is applied to Vitkovice to non-destructive testing of the steam generator tubes. The steam generator tube specimens, 16 mm by 1.5 mm, are made of AISI 321 steel with stress corrosion cracks. They were tested by the single-frequency eddy current inspection method.
M. Wilam, I. Čermáková
openaire   +1 more source

Flaw analysis in steam generator tubes

International Journal of Pressure Vessels and Piping, 1986
Abstract This paper presents the flaw assessment programme undertaken in France for PWR steam generator tubes affected by stress corrosion cracking. Failure criteria were deduced from burst tests on various crack configurations. Stresses and critical crack sizes were estimated for all operating conditions.
J.-P. Hutin, F. Billon
openaire   +1 more source

Damping of Steam Generator Tubes

Flow-Induced Vibration, 2003
The flow-induced vibration (FIV) analysis is one of the most critical evaluations needed to ensure long-term operation of steam generator. Original design hardware is usually based on experience and testing. Performance changes, such as an increase in power with increased feedwater flow, or tube repairs including plugs, stabilizers, and sleeves are ...
openaire   +1 more source

Selection of Tube Samples for Inservice Inspection of Steam Generator Tubes

Volume 7: Operations, Applications, and Components, 2005
In Pressurized Water Reactors, a program of periodic inservice inspection of steam generator tubes is set up to monitor the integrity of the tubes. The inservice inspection is performed using nondestructive examination techniques, e.g., eddy current testing.
Guy Roussel, Leon Cizelj
openaire   +1 more source

Evaluation of a steam generator tube rupture accident in an accelerator driven system with lead cooling [PDF]

open access: yesProgress in Nuclear Energy, 2008
A postulated steam generator tube rupture (SGTR) accident in a lead cooled accelerator driven transmuter (ADT) is investigated. The design of the ADT without intermediate loops bears the risk of water/steam blasting into the primary coolant.
W Maschek
exaly   +1 more source

Vibration Damping of Stabilized Steam-Generator Tubes

Volume 4: Fluid Structure Interaction, 2005
The integrity of steam-generator tubes is an important aspect of the long-term reliable operation of nuclear power plants. In situations where a tube is judged to be at risk, it must be either plugged, or removed, or reliably stabilized in some manner to avoid excessive motion of the tube due to flow-induced vibration.
V. P. Janzen   +3 more