Results 21 to 30 of about 369 (190)
The effective retrofit strategy of non-seismic designed structures is required to improve the strength and ductility. Jacketing is the most typical method which can enhance seismic resistance capacity, but there are many disadvantages due to its enlarged
Kyong Min Ro +3 more
doaj +1 more source
Numerical study of spun pile with steel jacket
Abstract The confinement ratio of spun piles manufactured in Indonesia has been a matter of concern since it does not meet the applicable requirements. Additional steel jacketing retrofitting was used to cope with the problem as well as improve the strength of spun pile to pile cap connection. A numerical study was performed to study the
J Reagen +3 more
openaire +1 more source
EXPERIMENTAL INVESTIGATION OF STRENGTHENED SHORT CONCRETE COLUMNS [PDF]
Reinforced concrete (RC) columns in buildings often need strengthening either due to defects in the columns themselves, having to support higher loads than those foreseen in the initial design of the structure, or as the result of ageing or accidental ...
KHALED MAHMOUD +2 more
doaj +1 more source
There has recently been growing interest in making a sustainable and durable fiber reinforced cementitious matrix (FRCM) to improve the seismic performance of RC column members.
Min-Su Jo +4 more
doaj +1 more source
This review highlights recent advances in integrating biocatalysis and chemocatalysis in continuous flow to create streamlined, sustainable processes. It examines chemo‐enzymatic cascades combining at least one enzymatic and one chemical step, discusses challenges such as enzyme immobilization, leaching, and reactor clogging, and presents solutions ...
Petros Siasiaridis +2 more
wiley +2 more sources
Assessment and Rehabilitation of Seismically Vulnerable Industrial RCC Structures [PDF]
The occurrence of building collapses or severe damages during powerful earthquakes has led to substantial economic losses, severe injuries, and loss of human lives.
Kamal Hosen
doaj +1 more source
Graphene nanoplatelet (0.1 wt.%) reinforcement significantly enhances the performance of β Ti‐28Nb‐35.4Zr alloy. Grain refinement, reduced water contact angle, and improved surface characteristics promote osteoblast adhesion and complete surface coverage after 7 days.
Khurram Munir +5 more
wiley +1 more source
Scandium (Sc)‐doped AlCoCrFeMo HEA coatings are fabricated via flame spraying with 0.1, 0.3, and 0.5 wt% Sc additions. Among these, the HEA‐Sc0.3 coating exhibits the highest corrosion resistance, indicated by a more positive corrosion potential and lower current density.
Pankaj Kumar +7 more
wiley +1 more source
The recent catastrophic seismic hazards have emphasized the crucial need for retrofitting structures built before adopting modern seismic building codes.
Hafiz Asfandyar Ahmed +2 more
doaj +1 more source
In seismic areas many buildings need to be retrofitted. In some cases, it is possible to apply carbon fiber-reinforcement polymer/plastic (CFRP), steel-jackets, and concrete jackets as rehabilitation methods.
A. Ismail
doaj +1 more source

