Parametric Analysis of New Assembled Double Steel Plate-Concrete Composite Shear Wall Structure
Cheng Hong+4 more
openalex +1 more source
This article presents a review of flat‐plate hybrid solar panels, focusing on four key aspects: system components, parameters affecting efficiency, monitoring, and applications of artificial intelligence. The use of hybrid solar panels represents a promising technology for the simultaneous generation of electrical and thermal energy from solar ...
Amy Zulema Velasco Bonilla+8 more
wiley +1 more source
Topology optimization of strut-and-tie models in steel plate shear walls
Ali Kheiri Marghzar+2 more
openalex +2 more sources
Integral throat entrance development, qualification and production for the Antares 3 nozzle [PDF]
Although design analyses of a G-90 graphite integral throat entrance for the Antares 3 solid rocket motor nozzle indicated acceptable margins of safety, the nozzle throat insert suffered a thermostructural failure during the first development firing ...
Clayton, F. I.+3 more
core +1 more source
Experimental Characterization of a Full‐Scale Stair System Detailed to Achieve Seismic Resiliency
ABSTRACT Stair systems are the primary means of egress in and out of a building during and after an earthquake. Therefore, it is essential to detail these critical nonstructural systems such that they remain operable during and after an earthquake of moderate to high levels of intensity.
Shokrullah Sorosh+6 more
wiley +1 more source
Investigation of cyclic behavior of steel-concrete composite coupling beams with axial rib corrugated webs. [PDF]
Liu Y, Sun F, Jiao L, Pan H, Xu D.
europepmc +1 more source
ABSTRACT A reinforced concrete waffle‐flat plate structure was subjected to a sequence of bidirectional near‐fault ground motions on a shake table until collapse. The test specimen was designed under current building codes and assigned a region of moderate seismicity.
Amadeo Benavent‐Climent+2 more
wiley +1 more source
Experimental Study on Shear Performance of Longitudinal Joints in Prefabricated Invert Arch for Mountain Mining Method Tunnels. [PDF]
Zhang S, Ma M, Li C, Ye P, Chen Z.
europepmc +1 more source
On the improvement of steel plate shear wall behavior, using energy absorbent element
Fereshteh Emami, Massood Mofid
openalex +1 more source
Seismic Testing and Performance Evaluation of Unitized Curtain Walls
ABSTRACT Unitized curtain walls are widely adopted in contemporary architecture for their lightweight construction, aesthetic qualities, ease of installation and high operational performance. They are particularly used in high‐rise buildings, where glazed facades are designed to meet a broad range of performance criteria.
Simona Bianchi+6 more
wiley +1 more source