Results 111 to 120 of about 278,365 (386)

Coexistence and Transition between Shear Zones in Slow Granular Flows

open access: yes, 2013
We report experiments on slow granular flows in a split-bottom Couette cell that show novel strain localization features. Nontrivial flow profiles have been observed which are shown to be the consequence of simultaneous formation of shear zones in the ...
Losert, Wolfgang   +5 more
core   +1 more source

Graded Hydroxyapatite Triply Periodic Minimal Surface Structures for Bone Tissue Engineering Applications

open access: yesAdvanced Healthcare Materials, EarlyView.
This study investigates the role of triply periodic minimal structures in load bearing bone tissue engineering applications. Research uses a combination of mechanical testing, material characterization, and in vitro tests to study the impact of TPMS lattice structures (gyroid, lidinoid and split‐P).
Tejas M. Koushik   +2 more
wiley   +1 more source

Seismic Performance and Flexural Capacity Analysis of Embedded Steel Plate Composite Shear Wall Structure with Fiber-Reinforced Concrete in the Plastic Hinge Zone

open access: yesBuildings
Due to its high axial bearing capacity and good ductility, the embedded steel plate composite shear wall structure has become one of the most widely used lateral force-resisting structural members in building construction.
Junlong Li, Guoqiang He, Jianbo Tian
doaj   +1 more source

Seismic Performance of Steel Pipe Pile to Cap Beam Moment Resisting Connections [PDF]

open access: yes, 2013
INE/AUTC 13 ...
Fulmer, Steven J.   +2 more
core  

Dexamethasone Delivery via Amphiphilic, Low‐swelling Hydrogels Treats Postoperative Inflammation in Cervical Spine Applications

open access: yesAdvanced Healthcare Materials, Volume 14, Issue 7, March 14, 2025.
DexaPatch, an implantable, low‐swelling amphiphilic hydrogel system containing dexamethasone‐PLGA microparticles, is developed and characterized for sustained local steroid release to reduce postoperative inflammation in tight surgical spaces. DexaPatch significantly reduces postoperative edema and fibrosis in a rabbit model of anterior spinal surgery,
Stephen W. Linderman   +6 more
wiley   +1 more source

Simplified Analytical Model and Shaking Table Test Validation for Seismic Analysis of Mid-Rise Cold-Formed Steel Composite Shear Wall Building

open access: yesSustainability, 2018
To develop the cold-formed steel (CFS) building from low-rise to mid-rise, this paper proposes a new type of CFS composite shear wall building system. The continuous placed CFS concrete-filled tube (CFRST) column is used as the end stud, and the CFS-ALC ...
Jihong Ye, Liqiang Jiang
semanticscholar   +1 more source

Reinforcement contribution to the behavior of low-rise concrete walls [PDF]

open access: yes, 2014
Based on steel strains recorded during shake table tests of six wall specimens, the effect and contribution of steel reinforcement to peak shear strength and displacement capacity of low-rise concrete walls is assessed and discussed.
Carrillo León, Julián   +2 more
core   +1 more source

Structural Motifs in Soft Fibrous Tissues: Revealing Structure‐Mechanics Relationships in Deformation and Tear Resistance for Biomimetic Material Design

open access: yesAdvanced Healthcare Materials, EarlyView.
This review explores how soft fibrous tissues achieve their remarkable mechanical behavior through recurring structural motifs across multiple length scales. It highlights key advances in mimicking these features using fiber‐reinforced hydrogels and hierarchical composites, offering insights into mechanical compatibility, flaw tolerance, and tear ...
Mirit Sharabi
wiley   +1 more source

Study of the effectiveness of outrigger system for high-rise composite buildings for cyclonic region [PDF]

open access: yes, 2011
The demands of taller structures are becoming imperative almost everywhere in the world in addition to the challenges of material and labor cost, project time line etc.
Fatima, Tabassum   +2 more
core   +2 more sources

Impact of Fiber Orientation in Electrospun PLA Scaffolds on Fluid Dynamics in a Custom Microfluidic Device

open access: yesAdvanced Healthcare Materials, EarlyView.
Fiber orientation in electrospun scaffolds affects permeability and fluid dynamics in microfluidic devices. Combining experimental data with computational fluid dynamic simulations, we show that aligned fibers enhance flow uniformity, reduce pressure and shear stress variability.
Elisa Capuana   +4 more
wiley   +1 more source

Home - About - Disclaimer - Privacy