Results 21 to 30 of about 119,541 (309)
Out-of-Plane Bending and Shear Behaviors of Steel Plate-Concrete Walls for Nuclear Power Plants
The steel plate-concrete structure, with its advantages of modular construction, good seismic capacity, and strong impact resistance, has been gradually replacing the reinforced concrete structure in the containment vessel and internal workshop structure
Zhihua Chen +3 more
doaj +1 more source
Numerical and parametrical investigations of the behavior of composite steel plate shear walls with opening [PDF]
The use of steel shear walls has been considered as a lateral load-bearing system in tall buildings. The significant advantage of Composite Steel Plate Shear Wall (CSPSW) is that the buckling of the infill steel plate, which is a serious disadvantage of ...
M. Ebadi Jamkhaneh, M. Ahmadi
doaj +1 more source
Seismic performance assessment of buildings with cold-formed steel shear wall panels [PDF]
Presented in this paper is a method for seismic performance assessment of cold-formed steel buildings built with shear wall panels as the lateral load resisting system.
Liu, Y., Martínez, J. M., Xu, L.
core +1 more source
The cold-formed steel-framed shear wall sheathed with steel sheet is widely used as a lateral force-resisting system for light-framed construction. However, the boundary conditions of the screw joint are not clear when steel is screwed to the frame.
Doo-Yong Lee, Bong-Ho Cho, Dam-I. Jung
doaj +1 more source
Analysis of steel plate shear walls
Structural engineering report SER 107 | SER-ID ...
Thorburn, L. Jane (Lorna Jane), 1958- +2 more
openaire +3 more sources
A steel plate shear wall often uses partially encased composite (PEC) columns instead of edge frame columns. Such a steel plate shear wall not only bears the gravity load of the structure and resists the bending moment caused by lateral force by taking ...
Zhanzhong Yin, Hui Zhang, Wenwei Yang
doaj +1 more source
The R&D Building of Zhanjiang Bay Laboratory is a high-rise structure with multiple irregular items exceeding the specification limit, employing a steel frame-shear wall structural system.
Tao Lan +4 more
doaj +1 more source
Surface damage resulting from rolling contact operating in magnetic field [PDF]
This paper describes the effects of magnetic field in rolling contact tests of steel by using a two-disc configuration and the investigation of mechanisms involved.
Iida, Y, Sato, K, Stolarski, T A
core +1 more source
A double-sided thin steel plate shear wall filled with rigid polyurethane foam (SWR) is proposed. A quasi-static monotonic loading test and quasi-static cycling loading test on shear behavior and the energy dissipation capacity of the SWR were carried ...
Renjie Liu +4 more
doaj +1 more source
EVALUATION OF THE INTERACTION OF STEEL SLIT PANEL-FRAME [PDF]
All buildings need a system that resists the lateral forces such as wind and earthquake. Such systems are commonly known as Lateral Force Resisting (LFR) Systems.
ahmad nazifi, Hashem Shariatmadar
doaj +1 more source