Results 251 to 260 of about 879,092 (307)
Some of the next articles are maybe not open access.
Journal of Hand Surgery, 2011
To investigate the mechanical properties of some common suture materials currently in use and compare them with a new multifilament stainless steel suture.We investigated the mechanical properties of 3-0 and 4-0 Fiberwire, 3-0 Supramid, 3-0 Ethibond, and a new 3-0 and 4-0 multifilament stainless steel suture. All suture material was tested in a knotted
Erik McDonald
exaly +3 more sources
To investigate the mechanical properties of some common suture materials currently in use and compare them with a new multifilament stainless steel suture.We investigated the mechanical properties of 3-0 and 4-0 Fiberwire, 3-0 Supramid, 3-0 Ethibond, and a new 3-0 and 4-0 multifilament stainless steel suture. All suture material was tested in a knotted
Erik McDonald
exaly +3 more sources
Is steel wire closure of sternotomy better than polyester suture closure?
Asian Cardiovascular and Thoracic Annals, 2014Introduction Median sternotomy is the preferred approach for open heart surgeries. The sternotomy incision is predominantly closed with either steel wire or polyester suture. The type of material used is primarily based on the surgeon’s choice, and both materials achieve a good result.
Pankaj Garg +2 more
exaly +3 more sources
Syneture Stainless STEEL Suture. A Collective Review of Its Performance in Surgical Wound Closure
Journal of Long-Term Effects of Medical Implants, 2006Syneture (division of U.S. Surgical, division of Tyco Healthcare, Norwalk, Connecticut, USA) STEEL sutures are monofilament stainless steel sutures composed of 316L stainless steel conforming to ASTM Standard F138 grade 2 (" Stainless steel bar and wire for surgical implant").
George T Rodeheaver +2 more
exaly +3 more sources
Journal of Foot and Ankle Surgery, 2009
A wide range of options is available to surgeons for fixation of the proximal interphalangeal joint when arthrodesis is undertaken for repair of the hammertoe deformity. In this technical report, we describe the use of an intraosseous loop of stainless-steel wire for permanent stabilization of the interface between the proximal and middle phalanges ...
William Harris, D Scot Malay
exaly +3 more sources
A wide range of options is available to surgeons for fixation of the proximal interphalangeal joint when arthrodesis is undertaken for repair of the hammertoe deformity. In this technical report, we describe the use of an intraosseous loop of stainless-steel wire for permanent stabilization of the interface between the proximal and middle phalanges ...
William Harris, D Scot Malay
exaly +3 more sources
ALLOY STEEL WIRE AS SUTURE MATERIAL FOR OPEN ANASTOMOSES OF THE LARGE INTESTINE†
Journal of the American Geriatrics Society, 1959G L Kratzer
exaly +3 more sources
Evaluation of multistrand stainless steel wire sutures
The American Journal of Surgery, 1962Abstract A preliminary report has been presented of the characteristics of a new multifilament stainless steel wire suture. It has been found to possess a high degree of flexibility and not to kink. When compared with sutures of silk, cotton and catgut of the same diameter, the wire suture was found to possess greater tensile strength and to cause ...
J, CONN, J M, BEAL
openaire +2 more sources
USE OF STAINLESS-STEEL SUTURES IN RHINOPLASTY
Archives of Otolaryngology - Head and Neck Surgery, 1952THE USE of stainless-steel septocolumellar sutures in cosmetic rhinoplasty is effective and practical in the prevention of secondary dropping of the nasal tip. The surgical technique commonly used in rhinoplasty has advanced to such an extent that one may be justified in expecting a highly satisfactory improvement in the appearance of the nose at the ...
openaire +2 more sources
Prevention of Wound Dehiscence by Use of Stainless-Steel Retention Sutures
JAMA, 1961Through-and-through wire stay sutures of stainless steel were used to reinforce the closure of the abdominal incision in 835 patients, mostly after operations on the upper abdomen. In 893 other patients who had mostly lower abdominal incisions stay sutures were not used. In each of these 2 groups there were 3 cases of dehiscence.
T J, ANGLEM, E B, GRAY
openaire +2 more sources
Comparison of the reaction of the cornea to nylon and stainless steel sutures: An animal study
Documenta Ophthalmologica, 1989In 11 rabbits a comparison was made between the reactions of the cornea to nylon and to stainless steel sutures, macroscopically and by means of scanning electron-microscopy (SEM). Macroscopically, the wounds sutured with steel thread showed much less reaction than the wounds sutured with nylon.
RIJNEVELD, WJ +3 more
openaire +3 more sources

