Fenestrated Aortic Stent Grafts [PDF]
Fenestrated stent grafts have been developed to offer an endovascular treatment option to those patients with abdominal aortic aneurysms whose infrarenal necks are anatomically unsuitable for endovascular repair with standard infrarenal devices. The ability to have customized fenestrations that will preserve flow to essential visceral arteries allows ...
James R H, Scurr, Richard G, McWilliams
openaire +2 more sources
Background Hemorrhage due to a ruptured splanchnic pseudoaneurysm followed by the formation of a postoperative pancreatic fistula is the most severe complication of a pancreatectomy, sometimes leading to a fatal outcome.
Masaru Nemoto +4 more
doaj +1 more source
Objective: This case highlights the clinical consequences of elastin (ELN) arteriopathy, which affects the supravalvular aorta, the branches of the arch and pulmonary arterial branches.
Pradeep Pravinkumar Mistry +5 more
doaj +1 more source
Effect of a Flared Renal Stent on the Performance of Fenestrated Stent-Grafts at Rest and Exercise Conditions [PDF]
Purpose: To quantify the hemodynamic impact of a flared renal stent on the performance of fenestrated stent-grafts (FSGs) by analyzing flow patterns and wall shear stress–derived parameters in flared and nonflared FSGs in different physiologic scenarios.
Hamady, M, Kandail, H, Xu, XY
core +2 more sources
Resection of thrombosed femoral artery over-dimensional stent-graft placed due to multiple arteriovenous fistulas following gunshot wounds [PDF]
Introduction. Though surgical approach is common in arteriovenous (AV) fistula treatment, endovascular procedures such as stent-graft placement has become more popular in recent years.
Radak Đorđe +10 more
doaj +1 more source
Computational fluid dynamicaccuracy in mimicking changes in blood hemodynamics in patients with acute type IIIb aortic dissection treated with TEVAR [PDF]
Background: We aimed to verify the accuracy of the Computational Fluid Dynamics (CFD) algorithm for blood flow reconstruction for type IIIb aortic dissection (TBAD) before and after thoracic endovascular aortic repair (TEVAR).
Domenig, Christoph +5 more
core +1 more source
Difficult diagnosis and management of a complicated Nellix graft infection
An 81-year-old man, with a complex vascular surgical history, presents with sepsis from an infected Nellix stent-graft. He required an urgent laparotomy, explantation of the graft, and extra-anatomical repair. Although now widely used for this indication,
Jin Xin Lin, MBChB +3 more
doaj +1 more source
Endovascular repair for acute traumatic transection of the descending thoracic aorta: experience of a single centre with a 12-years follow up [PDF]
Background: Most blunt aortic injuries occur in the proximal proximal descending aorta causing acute transection of this vessel. Generally, surgical repair of the ruptured segment of aorta is associated with high rates of morbidity and mortality and in
Butrico, L +6 more
core +2 more sources
Successful covered stent‐graft treatment of superficial femoral arterial injury due to blunt trauma
Background Endovascular treatment is used for traumatic arterial injuries in the torso. However, the effectiveness of endovascular covered stent‐graft treatment for peripheral artery injury is unclear. We present a case of superficial femoral artery (SFA)
Takatoshi Koroki +4 more
doaj +1 more source
We have reported a case of proximal anastomotic leakage excluded with the Najuta fenestrated stent graft after a surgeon-modified frozen elephant trunk aortic arch graft.
Hikaru Nakagawa, MD +4 more
doaj +1 more source