Results 11 to 20 of about 63,630 (301)

Stent graft treatment for ruptured pseudoaneurysms of the splanchnic arteries after pancreaticoduodenectomy: a case report

open access: yesSurgical Case Reports, 2020
Background Hemorrhage due to a ruptured splanchnic pseudoaneurysm followed by the formation of a postoperative pancreatic fistula is the most severe complication of a pancreatectomy, sometimes leading to a fatal outcome.
Masaru Nemoto   +4 more
doaj   +1 more source

Supravalvular aortic arch stenosis: A report of progressive disease and endovascular hybrid repair in a child

open access: yesAnnals of Vascular Surgery - Brief Reports and Innovations, 2022
Objective: This case highlights the clinical consequences of elastin (ELN) arteriopathy, which affects the supravalvular aorta, the branches of the arch and pulmonary arterial branches.
Pradeep Pravinkumar Mistry   +5 more
doaj   +1 more source

Effect of a Flared Renal Stent on the Performance of Fenestrated Stent-Grafts at Rest and Exercise Conditions [PDF]

open access: yes, 2016
Purpose: To quantify the hemodynamic impact of a flared renal stent on the performance of fenestrated stent-grafts (FSGs) by analyzing flow patterns and wall shear stress–derived parameters in flared and nonflared FSGs in different physiologic scenarios.
Hamady, M, Kandail, H, Xu, XY
core   +2 more sources

Fenestrated Aortic Stent Grafts [PDF]

open access: yesSeminars in Interventional Radiology, 2007
Fenestrated stent grafts have been developed to offer an endovascular treatment option to those patients with abdominal aortic aneurysms whose infrarenal necks are anatomically unsuitable for endovascular repair with standard infrarenal devices. The ability to have customized fenestrations that will preserve flow to essential visceral arteries allows ...
James R H, Scurr, Richard G, McWilliams
openaire   +2 more sources

Resection of thrombosed femoral artery over-dimensional stent-graft placed due to multiple arteriovenous fistulas following gunshot wounds [PDF]

open access: yesSrpski Arhiv za Celokupno Lekarstvo, 2010
Introduction. Though surgical approach is common in arteriovenous (AV) fistula treatment, endovascular procedures such as stent-graft placement has become more popular in recent years.
Radak Đorđe   +10 more
doaj   +1 more source

Difficult diagnosis and management of a complicated Nellix graft infection

open access: yesJournal of Vascular Surgery Cases and Innovative Techniques, 2021
An 81-year-old man, with a complex vascular surgical history, presents with sepsis from an infected Nellix stent-graft. He required an urgent laparotomy, explantation of the graft, and extra-anatomical repair. Although now widely used for this indication,
Jin Xin Lin, MBChB   +3 more
doaj   +1 more source

Biliary tract complications in human orthotopic liver transplantation [PDF]

open access: yes, 1987
The results of 393 consecutive orthotopic liver transplants in 313 patients were reviewed to determine the incidence of primary biliary tract complications.
Esquivel, CO   +6 more
core   +1 more source

Complete neck vessel preservation using a fenestrated stent graft for the treatment of proximal anastomotic leakage after open frozen elephant trunk graft aortic arch repair

open access: yesJournal of Vascular Surgery Cases and Innovative Techniques, 2022
We have reported a case of proximal anastomotic leakage excluded with the Najuta fenestrated stent graft after a surgeon-modified frozen elephant trunk aortic arch graft.
Hikaru Nakagawa, MD   +4 more
doaj   +1 more source

Open conversion after aortic endograft infection. Caused by colistin-resistant, carbapenemase-producing Klebsiella pneumoniae [PDF]

open access: yes, 2016
A 62-year-old man presented with fever, abdominal pain, and malaise 13 months after emergency endovascular aortic repair. Computed tomographic angiograms showed a periprosthetic fluid and gas collection, so infection was diagnosed. Open conversion was
Capoccia, Laura   +5 more
core   +1 more source

Computational fluid dynamicaccuracy in mimicking changes in blood hemodynamics in patients with acute type IIIb aortic dissection treated with TEVAR [PDF]

open access: yes, 2018
Background: We aimed to verify the accuracy of the Computational Fluid Dynamics (CFD) algorithm for blood flow reconstruction for type IIIb aortic dissection (TBAD) before and after thoracic endovascular aortic repair (TEVAR).
Domenig, Christoph   +5 more
core   +1 more source

Home - About - Disclaimer - Privacy