Results 81 to 90 of about 316,749 (274)
Bioimpedance real-time charazterization of neointimal tissue inside stents [PDF]
It is hereby presented a new approach to monitor restenosis in arteries fitted with a stent during an angioplasty. The growth of neointimal tissue is followed up by measuring its bioimpedance with Electrical Impedance Spectroscopy (EIS).
Huertas Sánchez, Gloria +6 more
core
ABSTRACT Backgrounds Accurate stent positioning in aorto‐ostial lesions remains challenging due to complex three‐dimensional anatomy, lack of optimal fluoroscopic projections, and high rates of geographic miss. Stent overhang impairs guide catheter re‐engagement and complicates future revascularization.
Gregor Leibundgut +7 more
wiley +1 more source
Timing of silicone stent removal in patients with post-tuberculosis bronchial stenosis
Context: In patients with post-tuberculosis bronchial stenosis (PTBS), the severity of bronchial stenosis affects the restenosis rate after the silicone stent is removed.
Jung Seop Eom +8 more
doaj +1 more source
Characterisation of the mechanobiology of stents in vitro [PDF]
This paper was presented at the 4th Micro and Nano Flows Conference (MNF2014), which was held at University College, London, UK. The conference was organised by Brunel University and supported by the Italian Union of Thermofluiddynamics, IPEM, the ...
4th Micro and Nano Flows Conference (MNF2014) +6 more
core
Advances in procedural techniques--antegrade. [PDF]
There have been many technological advances in antegrade CTO PCI, but perhaps most importantly has been the evolution of the "hybrid' approach where ideally there exists a seamless interplay of antegrade wiring, antegrade dissection re-entry and ...
Spratt, JC, Wilson, W
core +1 more source
ABSTRACT We present the case of a 56‐year‐old male with non‐ST elevation myocardial infarction (NSTEMI) and a complex thrombotic lesion at the ostial left circumflex artery (LCX), extending into bifurcating marginal branches. Due to the high risk of side branch occlusion, a stentless strategy using thrombus aspiration, the reverse wire technique, and ...
Flavius‐Alexandru Gherasie +1 more
wiley +1 more source
Background Self-expanding nitinol stent (SENS) implantation is commonly oversized in the superficial femoral artery (SFA), and leads to chronic outward force (COF) and in-stent restenosis (ISR).
Hu Li +15 more
doaj +1 more source
The Hybrid Approach to Intervention of Chronic Total Occlusions [PDF]
The "hybrid" approach to chronic total occlusion (CTO) percutaneous coronary intervention (PCI) was developed to provide guidance on optimal crossing strategy selection.
Banerjee, S +6 more
core +1 more source
Dealing with in-stent restenosis [PDF]
Stents have been shown to reduce the incidence of restenosis; however, they are not a cure. In two trials the angiographic restenosis rate was reported to be between 20% and 30% (in the Benestent II trial the unpublished quoted restenosis rate was 15%). These trials were based on stenting short, de novo lesions, in native coronary arteries.
A H, Gershlick, J, Baron
openaire +2 more sources
A Novel 3D Wiring Technique—ZOLUTION Zero Degree OverLap View Universal Three DimensIONal CTO Wiring
ABSTRACT We present a novel simple and easy‐to‐use 3D wiring technique for coronary chronic total occlusions (CTOs) named ZOLUTION—Zero OverLap View Universal Three dimensIONal wiring. ZOLUTION can be used for: (1) Distal cap puncture, (2) CTO body wiring, (3) Retrograde wiring, and (4) Reverse controlled antegrade and retrograde tracking (reverse CART)
Eugene B. Wu +16 more
wiley +1 more source

