Results 81 to 90 of about 79,377 (290)
ABSTRACT Introduction Moderate‐to‐severe calcification is present in ~20%–30% of patients undergoing coronary angiography. Coronary lesion modification is often necessary to facilitate optimal stent delivery and expansion, with several dedicated devices now approved for calcium modification before stent implantation. The CYCLOPES study aims to evaluate
Daniel O'Callaghan +14 more
wiley +1 more source
Perfil dos pacientes submetidos à angioplastia trasluminal coronariana com stents farmacológicos no Instituto de Cardiologia de Santa Catarina. [PDF]
Trabalho de Conclusão de Curso - Universidade Federal de Santa Catarina. Curso de Medicina.
Aquino, Vivian Wuerges de
core
Commissural Misalignment Following Valve‐in‐Valve Transcatheter Aortic Valve Implantation
ABSTRACT Background Data on commissural misalignment (CMA) during valve‐in‐valve transcatheter aortic valve implantation (ViV‐TAVI) for valve failure after surgical aortic valve replacement (SAVR) is scarce. Aims To study the impact of CMA on clinical and hemodynamic outcomes following ViV‐TAVI for failed SAVR.
Matthias Raschpichler +13 more
wiley +1 more source
ABSTRACT Coronary slow flow (SF) and no‐reflow (NR) are clinically significant complications of percutaneous coronary intervention (PCI), particularly in ST‐segment elevation myocardial infarction (STEMI) and saphenous vein graft (SVG) interventions. Angiographically defined as impaired myocardial perfusion despite restored epicardial patency, SF/NR ...
Bharat Khialani +5 more
wiley +1 more source
Effectiveness of Two-Year Versus One-Year Use of Dual Antiplatelet Therapy in Reducing the Risk of Very Late Stent Thrombosis After Drug-Eluting Stent Implantation [PDF]
Background: Impact of 12 months’ versus 24 months’ use of dual antiplatelet therapy on the prevalence of stent thrombosis in patients undergoing percutaneous coronary intervention (PCI) with the drug-eluting stent (DES) is not clear.
Ali Reza Amirzadegan +11 more
doaj +2 more sources
Design and testing of hydrophobic core/hydrophilic shell nano/micro particles for drug-eluting stent coating [PDF]
In this study, we designed a novel drug-eluting coating for vascular implants consisting of a core coating of the anti-proliferative drug docetaxel (DTX) and a shell coating of the platelet glycoprotein IIb/IIIa receptor monoclonal antibody SZ-21.
A Arsiwala +62 more
core +1 more source
SYNERGY Early Stent Thrombosis
SYNERGY (Boston Scientific, Marlborough, Massachusetts), the first metallic bioresorbable polymer drug-eluting stent (DES) approved by the U.S. Food and Drug Administration, incorporates design elements intended to expedite stent healing and enhance safety [(1)][1].
Dean J, Kereiakes, Juan F, Granada
openaire +2 more sources
Mechanistic Insights Into How Rewiring and Bifurcation Angle Affect DK‐Crush Stent Deployment
ABSTRACT Background Double kissing crush (DKC) is a preferred two‐stent technique for complex coronary bifurcation lesions. Proximal cell rewiring is routinely recommended to reduce technical failure, and DKC is considered effective across various bifurcation angles. However, it remains unclear whether this standard approach is optimal for all patients.
Andrea Colombo +6 more
wiley +1 more source
Gene Therapy for Cardiovascular Disease [PDF]
The last decade has seen substantial advances in the development of gene therapy strategies and vector technology for the treatment of a diverse number of diseases, with a view to translating the successes observed in animal models into the clinic ...
Baker, Andrew H. +3 more
core +4 more sources

