Results 121 to 130 of about 514,419 (396)
Carotid Artery Stent Continued Expansion Days After Deployment, Without Post Stent Deployment Angioplasty. [PDF]
This is a carotid artery stent (CAS) case report, which avoids post-stent deployment angioplasty (Post-SDA), with duplex confirmed continued stent expansion at 1, 3 and 30-day post deployment.
Arhuidese, Isibor+3 more
core +3 more sources
Ureteral stent technology: Drug-eluting stents and stent coatings
Ureteral stents are commonly used following urological procedures to maintain ureteral patency. However, alongside the benefits of the device, indwelling stents frequently cause significant patient discomfort (pain, urgency, frequency) and can become encrusted and infected.
Peter A. Cadieux+4 more
openaire +4 more sources
Exosome-eluting stents for vascular healing after ischaemic injury
Shiqi Hu+8 more
semanticscholar +1 more source
Comparison of Zotarolimus- and Everolimus-Eluting Coronary Stents
Background—Newer-generation drug-eluting stents that release zotarolimus or everolimus have been shown to be superior to the first-generation drug-eluting stents.
J. Iqbal+8 more
semanticscholar +1 more source
This review highlights recent advancements in 3DP techniques that incorporate emerging multifunctional SMP materials for applications in e‐electronics, soft actuators, biomedical devices, and more. Abstract Shape memory polymers (SMP) have recently gained significant attention as multifunctional materials for flexible and wearable electronics ...
Muhammad Yasir Khalid+4 more
wiley +1 more source
In-stent restenosis. Acute and long-term outcomes after excimer laser coronary angioplasty
OBJETIVE: With the increased use of intracoronary stents, in-stent restenosis has become a clinically significant drawback in invasive cardiology. We retrospectively assessed the short- and long-term outcomes after excimer laser coronary angioplasty of ...
Jorge Bejarano+4 more
doaj +1 more source
Mixed formulation of the one-dimensional equilibrium model for elastic stents [PDF]
In this paper we formulate and analyze the mixed formulation of the one-dimensional equilibrium model of elastic stents. The model is based on the curved rod model for the inextensible and ushearable struts and is formulated in the weak form in \v{C}ani\'
Grubišić, Luka+3 more
core +3 more sources
Integrating proprioceptive capabilities in balloon‐type robots enhances safe human–machine interactions. Traditional pressure estimates are inadequate due to nonlinear relationships. Instead, embedding stretchable sensors effectively measures deformation. This design optimizes sensor geometry to minimize damage risks.
Wenchao Yue+6 more
wiley +1 more source
Iatrogenic Arteriovenous Fistula Following Femoral Access Precipitating High-Output Heart Failure
Iatrogenic complications may manifest in a variety of ways. We present the case of an 86-year-old woman who underwent a percutaneous coronary intervention with a drug-eluting stent for non–ST-segment elevation myocardial infarction followed by leadless ...
Robert S. Zilinyi, MD+3 more
doaj
Multi‐Material Additive Manufacturing of Soft Robotic Systems: A Comprehensive Review
This review explores the transformative role of multi‐material additive manufacturing (MMAM) in the development of soft robotic systems. It presents current techniques, materials, and design strategies that enable functionally graded and adaptive structures.
Ritik Raj+2 more
wiley +1 more source