Results 71 to 80 of about 514,419 (396)

Pharmacokinetic analysis after implantation of everolimus-eluting self-expanding stents in the peripheral vasculature [PDF]

open access: yes, 2012
Background: A novel self-expanding drug-eluting stent was designed to release everolimus 225 mu g/cm(2) to prevent restenosis following peripheral arterial intervention.
Hausegger, Klaus A   +7 more
core   +2 more sources

Trial of everolimus-eluting stents or bypass surgery for coronary disease.

open access: yesNew England Journal of Medicine, 2015
BACKGROUND Most trials comparing percutaneous coronary intervention (PCI) with coronary-artery bypass grafting (CABG) have not made use of second-generation drug-eluting stents.
Seung‐Jung Park   +25 more
semanticscholar   +1 more source

Development of Substrate‐Independent Antifouling and Bactericidal Surfaces Using Visible Light Cross‐Linked Hydrogel Coatings for Biomedical Applications

open access: yesAdvanced Healthcare Materials, EarlyView.
A new antifouling, antithrombogenic, and bactericidal hydrogel coating method is developed for implantable medical devices. The hydrogel coating can be easily formed by visible‐light crosslinking and is universally applicable to all substrates, ranging from polymers to metals.
Soonjong Roh   +4 more
wiley   +1 more source

La broncoscopia rígida terapéutica en situación urgente. Análisis de nuestra casuística en 2019 [PDF]

open access: yesRevista SOCAMPAR, 2020
Introducción. La atención urgente con broncoscopia rígida intervencionista en casos de obstrucción severa de la vía aérea a pacientes seriamente comprometidos no es una situación habitual. Material y métodos.
Páez Codeso FM   +2 more
doaj  

Coronary Stents: History, Design, and Construction

open access: yesJournal of Clinical Medicine, 2018
The history of percutaneous coronary intervention (PCI) is marked by rapid technological advancements that have taken place over the past 40 years. After a period of balloon angioplasty, which was marred by risk of abrupt vessel closure and vessel recoil,
Torrey Schmidt, J. Abbott
semanticscholar   +1 more source

Dexamethasone Delivery via Amphiphilic, Low‐swelling Hydrogels Treats Postoperative Inflammation in Cervical Spine Applications

open access: yesAdvanced Healthcare Materials, Volume 14, Issue 7, March 14, 2025.
DexaPatch, an implantable, low‐swelling amphiphilic hydrogel system containing dexamethasone‐PLGA microparticles, is developed and characterized for sustained local steroid release to reduce postoperative inflammation in tight surgical spaces. DexaPatch significantly reduces postoperative edema and fibrosis in a rabbit model of anterior spinal surgery,
Stephen W. Linderman   +6 more
wiley   +1 more source

Robust optimization of cardiovascular stents: A comparison of methods [PDF]

open access: yes, 2004
This is the post-print version of the Article. The official published version can be accssed from the links below. Copyright @ 2004 Taylor & FrancisModern engineering design contains both creative and analytic components.
Atherton, MA, Bates, RA
core   +1 more source

Stent thrombosis and drug-eluting stents [PDF]

open access: yesJournal of Cardiology, 2011
Coronary stents have been used for the treatment of patients with coronary artery disease (CAD), and significantly improved procedural safety and are associated with a lower rate of restenosis compared with balloon angioplasty alone. Drug-eluting stents (DES) have been dominant for the treatment of CAD with efficacy in significantly reducing both ...
Takafumi Hiro   +2 more
openaire   +3 more sources

Long-term outcomes with drug-eluting stents versus bare-metal stents in Sweden.

open access: yesNew England Journal of Medicine, 2007
BACKGROUND Recent reports have indicated that there may be an increased risk of late stent thrombosis with the use of drug-eluting stents, as compared with bare-metal stents.
B. Lagerqvist   +5 more
semanticscholar   +1 more source

Controlled Magnesium Ion Delivery via Mg‐Sputtered Nerve Conduit for Enhancing Peripheral Nerve Regeneration

open access: yesAdvanced Healthcare Materials, EarlyView.
This study introduces a controllable degradation system for Mg‐based biomaterials using sputtering technology, marking a significant advancement in nerve regeneration research. The Mg‐sputtered nerve conduits demonstrate enhanced biocompatibility, biofunctionality, mechanical compatibility, and precise magnesium release, resulting in improved axonal ...
Hyewon Kim   +12 more
wiley   +1 more source