Results 161 to 170 of about 199,649 (279)

Multi-resolution tone mapping for high dynamic range medical ultrasound images. [PDF]

open access: yesPLoS One
Vu TLN   +4 more
europepmc   +1 more source

Hierarchical Twin Networks Enable Exceptional Strength and Fracture Toughness in Titanium

open access: yesAdvanced Science, EarlyView.
A commercial‐purity titanium with hierarchical ultrafine twin structures delivers an exceptional combination of fracture toughness (KJIc) of 187 MPa·m1/2 and specific yield strength of 140 MPa·cm3·g−1, in which pre‐engineered high‐density twin boundaries stimulate massive and dislocations to blunt crack tip.
Xiao‐Wei Zou  
+3 more
wiley   +1 more source

Bio‐Inspired Mechanical Amplification Block on Implantable Tactile Sensors

open access: yesAdvanced Electronic Materials, EarlyView.
 . ABSTRACT Implantable strain sensors offer opportunities for continuous biomechanical monitoring, but their performance deteriorates severely once embedded in soft tissue due to mechanical shielding that suppresses strain transmission to the sensing layer.
Sungbin Choi   +5 more
wiley   +1 more source

Microstructured Tactile Sensors With Bismuth Telluride Coatings for Vibration Detection

open access: yesAdvanced Electronic Materials, EarlyView.
The study reports a high‐performance piezoresistive vibration sensor (PVS) based on a Bi₀.5Sb₁.5Te3 functional layer on a PDMS microstructured substrate. The device exhibits high sensitivity (0.24 kPa−1), fast response, and excellent durability over 10 000 cycles.
Yikun Liu   +8 more
wiley   +1 more source

Intrinsic Mechanical Parameters and their Characterization in Solid‐State Lithium Batteries

open access: yesAdvanced Energy Materials, Volume 15, Issue 11, March 18, 2025.
This review focuses on the intrinsic mechanical parameters and their associated characterization in solid‐state batteries. The physical significance of mechanics parameters is introduced with exhaustive classifications by elastic, plastic deformations and fracture in bulk, adhesion, friction at interfaces, and mechanical fatigue in cells ...
Shuai Hao   +5 more
wiley   +1 more source

Fabrication of Composite Cathode for All‐Solid‐State Sodium Batteries

open access: yesAdvanced Energy Materials, EarlyView.
The design of composite cathodes for all‐solid‐state sodium batteries must address three critical challenges—interfacial side reactions, interfacial delamination, and highly tortuous transport pathways. This work outlines structural and interfacial strategies to optimize ion transport and mechanical stability, enabling durable, and high‐performance ...
Gaoming Sun   +6 more
wiley   +1 more source

Home - About - Disclaimer - Privacy