Results 21 to 30 of about 969,703 (351)

A New Dual Polarity Direct AC-AC Voltage Regulator Ensuring Voltage Step-Up and Step-Down Capabilities

open access: yesApplied Sciences, 2021
The problem of voltage sag and swell is one of the major reasons for low-quality power in the distribution system. Normally, it results from the system’s faults, including line-to-ground and line-to-line, non-linear characteristics of loads and sources ...
Naveed Ashraf   +6 more
doaj   +1 more source

Design considerations of asymmetric step-up/down dual-resonator charger for lithium-ion battery applications

open access: yesEnergy Reports, 2022
In Lithium-ion battery charging applications, wide step-up/down voltage gain range converters are commonly used. The resonant frequency ratio and quality factor can seriously affect the switching frequency range and voltage gain characteristics of the ...
Yubo Han   +6 more
doaj   +1 more source

Grid Grounding Calculations for a 132-KV Substation Using Soil Backfilling

open access: yesIEEE Access, 2019
Safe and reliable grid design is complicated by the compact design of gas insulated substations (GIS). This paper discusses the complete grounding design procedure for a 132-KV substation in the city of Al Kharj based on the IEEE-80 specifications and ...
Saeed Alyami
doaj   +1 more source

Novel Bidirectional Isolated DC/DC Converter with High Gain Ratio and Wide Input Voltage for Electric Vehicle Storage Systems

open access: yesBatteries, 2022
This study proposes a novel bidirectional isolated DC/DC converter with a high gain ratio and wide input voltage for electric vehicle (EV) storage systems.
Yu-En Wu, Chen-Han Tai
doaj   +1 more source

Horizontal Electric Field in the Vicinity of Structures Hit by Lightning

open access: yesAtmosphere, 2016
The horizontal electric field at the ground surface in the vicinity of structures hit by lightning flashes is relevant to the safety of human beings and livestock; it determines the touch and step voltages around the structure.
Celio Fonseca Barbosa
doaj   +1 more source

Impact of step voltage parameters on accuracy of evaluating XLPE insulation DC voltage endurance coefficient

open access: yesIET Generation, Transmission & Distribution, 2023
The voltage endurance coefficient n of cross‐linked polyethylene (XLPE) insulation is an important indicator for the analysis of insulation failure mechanism.
Zhipeng Ma   +7 more
doaj   +1 more source

Power Quality Improvement and Low Voltage Ride through Capability in Hybrid Wind-PV Farms Grid-Connected Using Dynamic Voltage Restorer [PDF]

open access: yes, 2018
© 2018 IEEE. Translations and content mining are permitted for academic research only. Personal use is also permitted, but republication/redistribution requires IEEE permission.This paper proposes the application of a dynamic voltage restorer (DVR) to ...
Allaoui, Tayeb   +3 more
core   +2 more sources

Impact of diffusion layers in strong electrolytes on the transient current [PDF]

open access: yes, 2009
Transient currents of electrolytes in response to a voltage step can reveal a lot about the behavior of charges present in an electrolyte. In this paper, electrolytes with high ionic strength are considered.
Beunis, Filip   +4 more
core   +1 more source

Tuning the onset voltage of resonant tunneling through InAs quantum dots by growth parameters [PDF]

open access: yes, 2002
We investigated the size dependence of the ground state energy in self-assembled InAs quantum dots embedded in resonant tunneling diodes. Individual current steps observed in the current-voltage characteristics are attributed to resonant single-electron ...
Hapke-Wurst, I.   +5 more
core   +4 more sources

Reducing the Effect of Lightning on Step and Touch Voltages in a Grounding Grid Using a Nature-Inspired Genetic Algorithm With ATP-EMTP

open access: yesIEEE Access, 2019
This paper discusses the step and touch voltages, based on body resistance, in a grounding grid after a lightning strike at a 434-/21-kV substation. To ensure grounding grid safety, the maximum step and touch voltage should not exceed the safety criteria
Saeid Gholami Farkoush   +5 more
doaj   +1 more source

Home - About - Disclaimer - Privacy