Results 291 to 300 of about 2,936,293 (339)
Some of the next articles are maybe not open access.
Power optimization of an endoreversible stirling cycle with regeneration
Energy, 1994Abstract An optimal power analysis is conducted on an endoreversible Stirling cycle with perfect regeneration. The endoreversible cycle is one in which the external heat transfer processes are the only irreversible processes of the cycle. Maximum power and efficiency at maximum power are obtained for the cycle based upon higher and lower temperature ...
David A. Blank+2 more
openaire +2 more sources
Multi objective ecological optimization of an irreversible Stirling cryogenic refrigerator cycle
Energy, 2023P. Prajapati+3 more
semanticscholar +1 more source
Analytical solution of heat transfer performance of pin-array stack regenerator in stirling cycle
, 2021Huanguang Wang+3 more
semanticscholar +1 more source
Estimation of limit cycle amplitude after onset threshold of thermoacoustic stirling engine
Experimental Thermal and Fluid Science, 2023Shu-Han Hsu, Yen-Ting Li
semanticscholar +1 more source
Working mechanism and characteristics of gas parcels in the Stirling cycle
, 2021G. Xiao, Qiu Hao, Kai Wang, Jintao Wang
semanticscholar +1 more source
An approach to the analysis of regenerators of stirling-cycle machines
International Journal of Refrigeration, 1992Abstract The governing equations of the regenerator of Stirling-cycle machines are derived by using the Lagrangian method in terms of the displacement of the displacer, so that time does not appear in the equations. A simplifying assumption is made that the heat transfer coefficient, based on the displacement of the displacer rather than time, is ...
openaire +3 more sources
MOPITT On-Orbit Stirling Cycle Cooler Performance
2002The Measurements of Pollution In The Troposphere (MOPITT) instrument was launched aboard the Terra spacecraft (formerly known as EOS AM-1), from Vandenburg Air Force Base, California on Dec 18th 1999. At present the instrument is in normal operations mode, having undergone its outgas and activation phases.
Gurpreet S. Mand+3 more
openaire +2 more sources
Reversed regenerative Stirling cycle machine for refrigeration application: A review
, 2020Muluken Z. Getie+4 more
semanticscholar +1 more source
Exergy Analysis of Stirling Cycle Cryogenerator
1998Exergy or the available work energy function is a useful concept for analysing various systems. This paper attempts to present exergy analysis for Stirling cycle cryogenerator. The cycle deviates from the ideal cycle due to (1) finite temperature difference (Δt) during heat transfer processes and (2) loss of refrigerating effect due to regenerator ...
openaire +2 more sources