Results 21 to 30 of about 9,229 (248)
The findings of cantilever beam bending tests conducted on a series of full-scale glass fibre-reinforced polymer (GFRP) and steel-reinforced concrete utility poles are presented. The poles were reinforced by (i) longitudinal steel bars and steel stirrups
Hassan Ahmadi +4 more
doaj +1 more source
Ashmolean Museum inventory no. AN1886.443&444. Iron, brass. Early 11th century. Two stirrup-irons inlaid with brass wire scrollwork and rectangular panels with vertical strips. The foot-plate is missing from the larger of the two stirrups.
Woruldhord Project Team (14251345)
core +1 more source
Prediction of Interface Shear Strength of Heat Damaged Shear-keys using Nonlinear Finite Element Analysis [PDF]
Push-off samples are simulated using nonlinear finite element analysis (NLFEA) to evaluate the effects of increased temperatures on the interface shear strength.
Rajai Z. Al-Rousan +1 more
doaj +1 more source
The article presents two previously unknown stirrups from the collections of the Krasnoyarsk Regional Mu-seum of Local Lore and the Minusinsk Regional Museum of N.M. Martyanov.
N.N. Seregin +2 more
doaj +1 more source
Residual Shear Capacity of RC Beams without Stirrups after Fire Exposure
To investigate the shear capacity and failure mechanism of RC beams after fire exposure, fourteen full-scale beams without stirrups were tested at ambient temperature and after fire exposure.
Yamin Song, Chuanguo Fu, Shuting Liang
doaj +1 more source
Bond capacity of severely corroded bars with corroded stirrups [PDF]
Eccentric pull-out tests were carried out to study the influence of severe corrosion leading to extensive cover cracking, and the effect of corroded and non-corroded stirrups on the anchorage of deformed bars.
Zandi, Kamyab +9 more
core +2 more sources
As is well known, corrosion of steel reinforcement deteriorates the steel–concrete interface and causes concrete cracking, degrading significantly the bond strength.
Konstantinos Koulouris +1 more
doaj +1 more source
– To improve the fragile nature of concrete, its low tensile strength, and a view to giving it the desired properties, which serve to build more durable structures at less cost, the association of a self-consolidating concrete with fiber, is considered a
Sihem Chaib*, Rachid Lassoued
doaj +1 more source
Nonlinear Numerical Assessment of Exterior Beam-Column Connections with Low-Strength Concrete
The ductility and capacity of reinforced concrete beam-column connections depend mainly on the concrete’s strength and the provided reinforcements. This study investigates numerically the role of low-strength concrete in beam-column joints utilizing ...
Basem S. Abdelwahed +2 more
doaj +1 more source
Steel fibres provide ductility to concrete structures. This, in turn, gives possibility to replace or reduce conventional reinforcement in structural elements.
Ulvis Skadiņš
doaj +1 more source

