Results 171 to 180 of about 621,076 (336)
Bone‐wise rigid registration of femur, tibia, and fibula for the tracking of temporal changes
Abstract Background Multiple myeloma (MM) induces temporal alterations in bone structure, such as osteolytic bone lesions, which are challenging to identify through manual image interpretation. The large variation in radiologists' assessments, even at expert centers, further complicates diagnosis.
Arttu Ruohola+5 more
wiley +1 more source
Abstract Purpose This study evaluates the technical feasibility of adapting a surface monitoring system, designed for conventional four‐dimensional computed tomography (4DCT), to an intelligent, breathing‐adapted 4DCT and examines its potential to expand the currently limited range of supported surrogate systems.
Niklas Lackner+4 more
wiley +1 more source
Abstract Purpose The purpose of the present study was to evaluate the impact of bone relative electron density (rED) assignment on radiotherapy planning for the abdominal region. Methods Twenty patients who received abdominal radiotherapy using MR‐Linac and underwent magnetic resonance imaging (MRI) and computed tomography (CT) simulation were analyzed.
Kota Abe+4 more
wiley +1 more source
Summary of best evidence for prevention of postoperative pulmonary complications after surgery for patients undergoing gastric cancer operations. [PDF]
Li M, Fu G, Mo W, Yan Y.
europepmc +1 more source
Oxyntic gland neoplasm of the stomach: expanding the spectrum and proposal of terminology
T. Ushiku+7 more
semanticscholar +1 more source
Abstract Purpose This study evaluates a novel cone‐beam computed tomography (CBCT) imaging solution integrated onto a conventional C‐arm linear accelerator (linac) with increased gantry speed. The purpose is to assess the impact of improved imaging hardware and reconstruction algorithms on image quality.
Theodore Arsenault+9 more
wiley +1 more source
Biomarkers used in the diagnosis and prognosis of gastric cancer in young patients: a scientometric analysis. [PDF]
Azbergenov NK+6 more
europepmc +1 more source
Abstract Purpose The aim of this study was to investigate the influence of the simultaneous multislice acceleration (SMS) technique as well as two‐dimensional (2D) and three‐dimensional (3D) tumor segmentations on radiomics features (RFs) within the parametric maps of cervical cancer, which were computed by intravoxel incoherent motion (IVIM) and ...
Shuangquan Ai+6 more
wiley +1 more source
Gastric Epithelioid Mesenchymal Tumor with the <i>EWSR1::CREM</i> Fusion Gene: A Case Report. [PDF]
Yoshizawa N+4 more
europepmc +1 more source
Abstract Current radiotherapy practices rely on manual contouring of CT scans, which is time‐consuming, prone to variability, and requires highly trained experts. There is a need for more efficient and consistent contouring methods. This study evaluated the performance of the Varian Ethos AI auto‐contouring tool to assess its potential integration into
Robert N. Finnegan+6 more
wiley +1 more source