Results 21 to 30 of about 6,312 (279)

Response of Buildings with Inclined First-Story Columns to Near-Fault Ground Motion [PDF]

open access: yesJournal of Rehabilitation in Civil Engineering, 2014
In this paper a simple model of a three story building with inclined first-story columns has presented. The stories are supposed to be rigid and are connected to axially rigid mass less columns by elasto-plastic rotational springs and linear rotational ...
Fouzieh Rouzmehr, Reza Saleh Jalali
doaj   +1 more source

Comparative Response Spectrum Analysis on 15- and 50-Story Reinforced Concrete Buildings Having Shear Walls with and without Openings as per EN1998-1 Seismic Code

open access: yesBuildings, 2023
Medium-rise reinforced concrete (RC) framed apartment complexes with stories ranging from 15 to 50 are becoming more common in Ethiopia’s main cities. In these RC-framed structures, shear walls are included for lateral load resistance.
Mistreselasie Abate   +2 more
doaj   +1 more source

Fragility analysis of the self-centering prestressed concrete frame with web friction devices [PDF]

open access: yesMATEC Web of Conferences, 2019
A novel self-centering prestressed concrete (SCPC) beam-column connection with web friction devices has been recently proposed for moment-resisting concrete frames.
Song Lianglong   +3 more
doaj   +1 more source

Seismic behavior of MSCSS based on story drift and failure path [PDF]

open access: yesLatin American Journal of Solids and Structures, 2021
Abstract The Mega-Sub Controlled Structure System (MSCSS) is a new type of seismic structural system. This research aims to find weak members in the structure and better describe the failure state. To achieve this, we enhanced the story drift ratio indicator by combining it with the structural failure path and proposed a new comprehensive indicator ...
Buqiao Fan   +4 more
openaire   +2 more sources

Seismic Retrofitting of Steel Frames with Buckling Restrained and Ordinary Concentrically Bracing Systems with Various Strain Hardening and Slenderness Ratios [PDF]

open access: yesJournal of Rehabilitation in Civil Engineering, 2014
The present study assesses the seismic performance of steel moment resisting frames (SMFs) retrofitted with different bracing systems. Two structural configurations were utilized: ordinary concentrically braces (OCBFs), buckling-restrained braces (BRBFs).
Gholamreza Abdollahzadeh   +2 more
doaj   +1 more source

Evaluation of Seismic Behavior of Steel Shear Wall by Time History Analysis [PDF]

open access: yesComputational Engineering and Physical Modeling, 2019
Reducing the vulnerability of buildings against earthquakes is one of the most important issues for engineers and public concern in the last decade. For designers, choosing the best option among the different lateral bracing systems that exist in terms ...
Hosein Bakhshi   +2 more
doaj   +1 more source

Seismic damage assessment of subway station subjected to mainshock-aftershock sequences

open access: yesYantu gongcheng xuebao, 2023
In the previous seismic analyses of underground structures, only the peak structural response under the main earthquake is considered, but the damage mechanism of underground structures subjected to sequential ground motions has not been fully understood
ZHONG Zilan 1, FENG Liqian 1, SHI Yuebo 1, WEN Weiping 2, 3, ZHAO Mi 1
doaj   +1 more source

Evaluating of Relative and Absolute Cumulative Input Energy Time History subjected to Forward Directivity Earthquakes [PDF]

open access: yesNumerical Methods in Civil Engineering, 2021
In this article, to study the effect of pulse-type near-fault earthquakes on the seismic demands of steel moment frames, 15-story 2D-frame was analyzed under the influence of 20 near-fields with forward directivity effect and 2 far-field records.
Navid Siahpolo   +2 more
doaj   +1 more source

Evaluation of seismic design provisions for a drift and inter-story drift relationship [PDF]

open access: yesWIT Transactions on The Built Environment, 2015
Maximum roof drift (RD) and inter-story drift (ISD) demands are important seismic design parameters since they are used to evaluate seismic hazard levels and performance state for structures located in seismic regions. ISD demand, especially, is an important seismic design parameter for evaluation of seismic performance of both structural and non ...
openaire   +1 more source

Seismic performance of damaged frame retrofitted with self-centering and energy-dissipating rocking wall

open access: yesResilient Cities and Structures, 2023
This paper proposes the novel concept of retrofitting damaged reinforced concrete frame with self-centering and energy-dissipating rocking wall. Parametric studies were carried out base on pushover and time-history analysis.
Genqi Xiao, Haishen Wang, Peng Pan
doaj   +1 more source

Home - About - Disclaimer - Privacy