Results 51 to 60 of about 5,972 (206)

Assessment method for identification of electrical connectivity and thermal stability of power grid

open access: yesThe Journal of Engineering, 2019
Primary equipment failure in substation has a significant impact on the reliability of the power supply, and even threatens the thermal stability of power grid.
Yao-Yu Xu   +5 more
doaj   +1 more source

Mechanism of Quasi‐Power‐Frequency Resonant Overvoltage Triggered by Multiple Lightning Strikes in High‐Voltage Alternating Current Systems Equipped With Shunt Reactor

open access: yesHigh Voltage, EarlyView.
ABSTRACT This paper investigates the generation mechanism of quasi‐power‐frequency resonant overvoltage triggered by multiple lightning strikes in high‐voltage alternating current (HVAC) systems equipped with shunt reactors. Based on field measurements from a 500 kV AC system, equivalent and simplified circuit models have been established to analyse ...
Tao Liang   +7 more
wiley   +1 more source

Identification of Low‐Value Defects in Infrared Images of Porcelain Insulators Based on STCE‐YOLO Algorithm

open access: yesEnergy Science & Engineering
Insulators, as a key component of the power system, their low‐value defect detection is of great significance to ensure the safe and stable operation of the power system.
Shaotong Pei   +6 more
doaj   +1 more source

Study on the Coupled Effects of High‐Speed Airflow and Charged Sand on Power‐Frequency Discharge Characteristics of Conductor–Tower Gaps in Strong Wind–Sand Environments

open access: yesHigh Voltage, EarlyView.
ABSTRACT Strong wind–sand weather in Xinjiang threatens power grid safety by increasing transmission line tripping risks. Existing studies focus on sand polarization but neglect the coupled influence of high‐speed airflow and charged sand on gap discharge characteristics.
Jianghai Geng   +8 more
wiley   +1 more source

Wave‐Velocity‐Based Temperature Monitoring Applied to Underground Power Cables in Medium‐Voltage Networks—Discrimination of Individual Cable Temperatures in a Distribution Grid

open access: yesHigh Voltage, EarlyView.
ABSTRACT The thermal state of underground power cables can be monitored based on the temperature dependency of the dielectric permittivity of the insulation material. The resulting temperature‐dependent wave velocity is used as a thermometric property. To this end, the signal propagation time along a cable of an injected signal is determined.
Peter Wouters   +2 more
wiley   +1 more source

Refined Safety Distance Measurement of Heavy Construction Machinery Near Electricity Operation Based on Feature‐Homogenised Spatial Target Analysis

open access: yesHigh Voltage, EarlyView.
ABSTRACT Heavy construction machinery is essential for power infrastructure construction and maintenance, making safety distance measurement crucial for ensuring operational safety. Existing methods, which rely on target space mapping, face challenges such as error accumulation and limited accuracy.
Fuqi Ma   +4 more
wiley   +1 more source

Implementation of an IEC 61850 Sampled-Value-Based Line Protection Scheme for a 132 kV System

open access: yesEngineering Proceedings
The paper details the implementation and experimental validation of an IEC 61850-9-2 sampled value (SV)-based distance protection scheme for a 132 kV transmission line.
Mathias Natangwe Shimwetheleni   +1 more
doaj   +1 more source

An Overview of High‐Temperature Superconducting Cables in DC Systems: Unlocking Potential for High‐Voltage DC Networks

open access: yesHigh Voltage, EarlyView.
ABSTRACT This paper provides an overview of high‐temperature superconducting (HTS) cables in DC systems, with a focus on their deployment in high‐voltage DC (HVDC) networks. The assessment of HTS cable properties—such as extremely low electrical resistance, high current‐carrying capacity and a compact geometry—and their comparison with those of ...
Mohammad Hossein Mousavi   +2 more
wiley   +1 more source

Lead-Acid Battery Sizing for a DC Auxiliary System in a Substation by the Optimization Method

open access: yesEnergies, 2019
Lead-acid batteries are the most frequently used energy storage facilities for the provision of a backup supply of DC auxiliary systems in substations and power plants due to their long service life and high reliability. It is possible to define the load
Janez Ribič   +4 more
doaj   +1 more source

Temperature Extraction Scheme for Composite Insulator Core Rod Sheath of Overhead Transmission Lines Based on Oriented Bounding Boxes

open access: yesHigh Voltage, EarlyView.
ABSTRACT Unmanned Aerial Vehicle (UAV) inspection of overhead transmission line composite insulators allows for the rapid acquisition of large amounts of infrared images of insulators in service, which can be used to analyse their operational status. However, efficiently and accurately analysing these images remains a challenge.
Zhenan Zhou   +7 more
wiley   +1 more source

Home - About - Disclaimer - Privacy