Results 51 to 60 of about 23,177 (239)

Response of Common and Tepary Bean Genotypes to Three Macrophomina phaseolina Isolates Inoculated at Different Growth Stages

open access: yesHortScience
Ashy stem blight caused by the fungus Macrophomina phaseolina (Tassi) Goidanich affects Phaseolus spp. in all growth stages. The identification of genotypes with durable resistance is crucial for disease management.
Roberto Vázquez III   +2 more
doaj   +1 more source

Assessment method for identification of electrical connectivity and thermal stability of power grid

open access: yesThe Journal of Engineering, 2019
Primary equipment failure in substation has a significant impact on the reliability of the power supply, and even threatens the thermal stability of power grid.
Yao-Yu Xu   +5 more
doaj   +1 more source

A Novel Digital Twin Platform for Accelerating Power Systems Restoration

open access: yesEnergy Internet, EarlyView.
Hardware Architecture Design of DT System in Laboratory. ABSTRACT With the global energy structure transforming towards the goal of net zero emissions, the penetration of an inverter‐based resource (IBR) in power systems is increasing. This transformation poses two critical challenges: the system post blackout restoration process becomes extremely ...
Yiliang Fan   +8 more
wiley   +1 more source

Former electricity substation, Merryoaks, Durham City: archaeological building recording (OASIS ID: archaeol3-355311)

open access: yes, 2019
Level 2 survey of a brick substation building. The building was constructed betweem 1898 and 1919 and substantially enalrged before 1939.
Linda Bosveld
core   +1 more source

Comparison of the Agronomic Performance between a Pigeonpea Hybrid and Five Breeding Lines Developed through Conventional Breeding

open access: yesHortScience
Pigeonpea [Cajanus cajan (L.) Mill.] may have cross- or self-pollination that allows the use of hybrids or improved genotypes by conventional breeding approaches in pigeonpea production.
Roberto III Vázquez   +2 more
doaj   +1 more source

Regional Infrared and Visible Image Registration for Distribution Substation Areas With Wide Depth of Field

open access: yesHigh Voltage, EarlyView.
ABSTRACT Infrared and visible image registration is a key task in automated distribution network inspection. Previous approaches typically apply a single homography to align infrared and visible images leading to local misalignment. To address this, this study proposes a novel region‐based registration algorithm specifically designed for wide‐depth ...
Yingchen Zhang, Bo Wang, Fei Tang
wiley   +1 more source

Identification of Low‐Value Defects in Infrared Images of Porcelain Insulators Based on STCE‐YOLO Algorithm

open access: yesEnergy Science & Engineering
Insulators, as a key component of the power system, their low‐value defect detection is of great significance to ensure the safe and stable operation of the power system.
Shaotong Pei   +6 more
doaj   +1 more source

An Improved Fast Computational Method for Vibration Characteristic Analysis of Dry‐Type Iron Core Reactor

open access: yesHigh Voltage, EarlyView.
ABSTRACT Structural mechanics field simulation plays a critical role in the vibration characteristic analysis of electrical equipment. Existing structural field analysis of equipment based on numerical simulation faces challenges such as convergence difficulties and prolonged computational time, failing to meet the demand for real‐time prediction of ...
Wanqing Wang   +6 more
wiley   +1 more source

Comparison of Dielectric Recovery After Arc Burning in SF6 Gas and Its Potential Alternatives

open access: yesHigh Voltage, EarlyView.
ABSTRACT Although sulphur hexafluoride (SF6) exhibits exceptional insulating properties, it is a potent greenhouse gas. Therefore, studying alternatives to SF6 is critical for developing environmentally friendly high‐voltage electrical equipment.
Ziqi Liu   +4 more
wiley   +1 more source

Computation of transient electromagnetic fields due to switching in high voltage substations

open access: yes, 2010
Switching operations of circuit breakers and disconnect switches radiate transient electromagnetic fields within high-voltage substations. The generated fields may interfere and disrupt normal operations of electronic equipment.
Siew, W.H., Musa, B.U., Judd, M.D.
core   +1 more source

Home - About - Disclaimer - Privacy