Results 41 to 50 of about 12,104 (222)
Use of synchronized vector measurements technology for perform relay protection functions
RELEVANCE. Recently, along with the initial scope of synchronized vector measurements (synchrophasor) technology associated with Wide Area Measurement System (WAMS), more and more attention is paid to expanding the scope of this technology.
R. G. Mustafin, V. A. Kasimov
doaj +1 more source
Laboratory testing of the communication based protection relays [PDF]
The proper operation of control and protection applications in Substation Automation System (SAS) demands very high-speed and reliable communications that has being achieved by using IEC 61850.
Daboul, M., Wasserbauer, V.
core
Power optimization for a hydrocarbon industrial plant using a genetic algorithm [PDF]
In this paper, a genetic algorithm (GA) is considered for optimizing electrical power loss for a real hydrocarbon industrial plant as a single objective problem.
Abido, MA, Al-Hajri, MT, Darwish, MK
core +1 more source
By manipulating current and voltage measurements, an assailant can induce unwanted relay action while attempting to avoid detection. Detecting advanced cyber intrusions in power protection environments requires specialised data analysis and anomaly detection methods.
Feras Alasali +6 more
wiley +1 more source
The level of protection of high voltage power substations depends on the considerations of the electricity company, the level of threats and the value of their assets. On the other hand, the level of countermeasures or defenses for an acceptable level of
Yongcai Xiao +4 more
doaj +1 more source
ABSTRACT Data from five rocket‐triggered lightning flashes are adopted to analyse the correlated transient response of buried cables and lightning channel radiations. These five flashes have the same termination point that is right above the buried cables and involve a total of 32 return strokes.
Mi Zhou +9 more
wiley +1 more source
ABSTRACT Infrared and visible image registration is a key task in automated distribution network inspection. Previous approaches typically apply a single homography to align infrared and visible images leading to local misalignment. To address this, this study proposes a novel region‐based registration algorithm specifically designed for wide‐depth ...
Yingchen Zhang, Bo Wang, Fei Tang
wiley +1 more source
S-GoSV: Framework for Generating Secure IEC 61850 GOOSE and Sample Value Messages
Standardized communication plays an important role in substation automation system (SAS). IEC 61850 is a de-facto standard in SAS. It facilitates smooth communication between different devices located in the substation by achieving interoperability ...
Shaik Mullapathi Farooq +2 more
doaj +1 more source
ABSTRACT Tree‐contact single‐phase‐to‐ground fault (TSF) is a common and hazardous type of failure in distribution networks. TSF is likely to occur when overhead conductors contact moist tree branches, potentially leading to insulation breakdown, posing serious threats to grid safety.
Wenjun Ning +5 more
wiley +1 more source
SEABASS: Symmetric-keychain Encryption and Authentication for Building Automation Systems [PDF]
There is an increasing security risk in Building Automation Systems (BAS) in that its communication is unprotected, resulting in the adversary having the capability to inject spurious commands to the actuators to alter the behaviour of BAS.
Keoh, Sye Loong +3 more
core +1 more source