Results 71 to 80 of about 14,343 (257)
Comparison of Dielectric Recovery After Arc Burning in SF6 Gas and Its Potential Alternatives
ABSTRACT Although sulphur hexafluoride (SF6) exhibits exceptional insulating properties, it is a potent greenhouse gas. Therefore, studying alternatives to SF6 is critical for developing environmentally friendly high‐voltage electrical equipment.
Ziqi Liu +4 more
wiley +1 more source
Development of online monitor for substation 10 kV MOA
Metal oxide arresters (MOA) are widely used for over-voltage protection of power facilities in 10 kV distribution networks, and it is hard to determine the failure ones. This study presented an online monitor for 10 kV MOA used in substation.
Xinming Song +4 more
doaj +1 more source
Rare Lightning and Convection Characteristics During Two Successive Tornadoes in Southern China
ABSTRACT Systematic investigations into lightning characteristics of tornado storms in China remain scarce. This study comprehensively analyses rare lightning behaviour and overshooting top characteristics for two successive tornadoes during a long‐lived supercell in southern China on 27 April 2024.
Fengquan Li +9 more
wiley +1 more source
Cybersecurity Testing Technology in Smart Substations [PDF]
In this chapter, a comprehensive and realistic cyber-physical test-bed has been built to investigate potential cybersecurity vulnerabilities and the impact of cyberattacks on IEC 61850-based smart substations.
Yi Yang +11 more
core +1 more source
The studies on strategies for improving restoration times in electrical distribution systems are extensive. They have theoretically explored the application of mathematical models, the implementation of remotely controlled systems, and the use of digital
Carlos Sánchez-Ixta +3 more
doaj +1 more source
Research and Application of One-key Sequence Control Technology for Substations [PDF]
The substations are important parts of modern electrical grids. In this sense, it is necessary to enhance the management efficiency and robustness of the substations.
Li-Qing Ge +3 more
doaj +1 more source
ABSTRACT Tree‐contact single‐phase‐to‐ground fault (TSF) is a common and hazardous type of failure in distribution networks. TSF is likely to occur when overhead conductors contact moist tree branches, potentially leading to insulation breakdown, posing serious threats to grid safety.
Wenjun Ning +5 more
wiley +1 more source
Research on optimisation of minimum air clearance of 1000 kV UHV AC substation
Based on air clearance discharge characteristic curve and insulation coordination method, it is pointed out that the minimum air clearance of 1000 kV ultra-high voltage (UHV) AC substation can be further optimised.
Li Zhenqiang +3 more
doaj +1 more source
ABSTRACT This paper investigates the generation mechanism of quasi‐power‐frequency resonant overvoltage triggered by multiple lightning strikes in high‐voltage alternating current (HVAC) systems equipped with shunt reactors. Based on field measurements from a 500 kV AC system, equivalent and simplified circuit models have been established to analyse ...
Tao Liang +7 more
wiley +1 more source
Electric power substations engineering [PDF]
This book covers all aspects of substations, from the initial concept to design, automation, operation, and physical and cyber security. Written by members of the Institute of Electrical and Electronic Engineers (IEEE) Power Engineering Society (PES ...
McDonald, John D
core