Results 61 to 70 of about 3,739 (205)
Rare Lightning and Convection Characteristics During Two Successive Tornadoes in Southern China
ABSTRACT Systematic investigations into lightning characteristics of tornado storms in China remain scarce. This study comprehensively analyses rare lightning behaviour and overshooting top characteristics for two successive tornadoes during a long‐lived supercell in southern China on 27 April 2024.
Fengquan Li +9 more
wiley +1 more source
An Investigation into Substation Grounding and Its Implementation on Gaza Substation
An investigation into the optimal design of a substation grounding system for the transmission substation in Gaza City, Palestine has been carried out. A research into the most influential parameters on the effectiveness of the substation grid system has been performed and its results have been incorporated into the Gaza case study.
Ahmed Hammuda +2 more
openaire +2 more sources
ABSTRACT Tree‐contact single‐phase‐to‐ground fault (TSF) is a common and hazardous type of failure in distribution networks. TSF is likely to occur when overhead conductors contact moist tree branches, potentially leading to insulation breakdown, posing serious threats to grid safety.
Wenjun Ning +5 more
wiley +1 more source
Techno-economic evaluation of power electronics-assisted transmission system frequency regulation
In many future power systems, the power generation may be predominantly supplied from converter interfaced sources (i.e. wind, solar, HVDC interconnection).
Rakibuzzaman Shah +3 more
doaj +1 more source
ABSTRACT This paper investigates the generation mechanism of quasi‐power‐frequency resonant overvoltage triggered by multiple lightning strikes in high‐voltage alternating current (HVAC) systems equipped with shunt reactors. Based on field measurements from a 500 kV AC system, equivalent and simplified circuit models have been established to analyse ...
Tao Liang +7 more
wiley +1 more source
Purpose. The purpose of the work is to develop the fundamentals of the design methodology of grounding system design of substations with open switchgears 330 (220) kV, which is aimed at ensuring electromagnetic compatibility of secondary circuits of ...
O. Yu. Glebov +3 more
doaj +1 more source
ABSTRACT Strong wind–sand weather in Xinjiang threatens power grid safety by increasing transmission line tripping risks. Existing studies focus on sand polarization but neglect the coupled influence of high‐speed airflow and charged sand on gap discharge characteristics.
Jianghai Geng +8 more
wiley +1 more source
The analysis made has shown expediency of modernization rather than reconstruction of earth electrodes, after inspection of long operating substations grounding grids, via building a two-level structure.
I.V. Nizhevskiy, V.I. Nizhevskiy
doaj
ABSTRACT The disintegration behaviour of ice‐melting droplets aggravates the discharge risk of ice‐covered insulators and the disintegration characteristics of droplets at applied voltages exceeding the critical discharge voltage lack in‐depth study.
Lin Yang +6 more
wiley +1 more source
ABSTRACT The thermal state of underground power cables can be monitored based on the temperature dependency of the dielectric permittivity of the insulation material. The resulting temperature‐dependent wave velocity is used as a thermometric property. To this end, the signal propagation time along a cable of an injected signal is determined.
Peter Wouters +2 more
wiley +1 more source

