Analysis of the Restoration of Distribution Substations: A Case Study of the Central–Western Division of Mexico

open access: yesEnergies
The studies on strategies for improving restoration times in electrical distribution systems are extensive. They have theoretically explored the application of mathematical models, the implementation of remotely controlled systems, and the use of digital
Carlos Sánchez-Ixta   +3 more
doaj   +1 more source

AccES: A Framework for Predicting Building‐Level Loss of Accessibility to Essential Services Post‐Disasters Based on Publicly Available Information [PDF]

open access: yesRisk Anal
ABSTRACT Natural hazards significantly disrupt access to essential services, affecting individuals' capacity to withstand and recover from such events. However, existing hazard resilience models often fail to account for the interdependencies among essential services and lack the spatial resolution needed to assess accessibility loss at the building ...
Pagan‐Cajigas Z, Guikema S.
europepmc   +2 more sources

STANDARDS IN CONTROL AND PROTECTION TEHNOLOGY FOR ELECTRIC POWER SYSTEMS [PDF]

open access: yes
The features of the standard IEC 16850 with respect to intelligent applications in substations are summarized. It is shown how modeling of functions independently from its allocation to devices allows optimizing existing applications and opening up for ...
Sergiu St. ILIESCU   +3 more
core   +2 more sources

Georeferentiation of CORE-TSO substations with OSM

open access: yes, 2023
The data is in the form of a CSV table that identifies the components of the transmission grid operators (substations, transformers, and lines) in AT, BE, CZ, DE, FR, HU, HR, LU, NL, PL, RO, SI, and SK given in the Core-TSO data: https://www.jao.eu ...
Raventos Morera, Oriol
core   +1 more source

Wave‐Velocity‐Based Temperature Monitoring Applied to Underground Power Cables in Medium‐Voltage Networks—Discrimination of Individual Cable Temperatures in a Distribution Grid

open access: yesHigh Voltage, EarlyView.
ABSTRACT The thermal state of underground power cables can be monitored based on the temperature dependency of the dielectric permittivity of the insulation material. The resulting temperature‐dependent wave velocity is used as a thermometric property. To this end, the signal propagation time along a cable of an injected signal is determined.
Peter Wouters   +2 more
wiley   +1 more source

Installation vessels for floating wind offshore substations [PDF]

open access: yes
This paper addresses the selection of optimal installation vessels for the assembly of offshore wind substations so as to reduce costs. Various options are available for substations, namely fixed, floating, and subsea.
A Crowle (21928691)
core   +3 more sources

Research on optimisation of minimum air clearance of 1000 kV UHV AC substation

open access: yesThe Journal of Engineering, 2019
Based on air clearance discharge characteristic curve and insulation coordination method, it is pointed out that the minimum air clearance of 1000 kV ultra-high voltage (UHV) AC substation can be further optimised.
Li Zhenqiang   +3 more
doaj   +1 more source

Refined Safety Distance Measurement of Heavy Construction Machinery Near Electricity Operation Based on Feature‐Homogenised Spatial Target Analysis

open access: yesHigh Voltage, EarlyView.
ABSTRACT Heavy construction machinery is essential for power infrastructure construction and maintenance, making safety distance measurement crucial for ensuring operational safety. Existing methods, which rely on target space mapping, face challenges such as error accumulation and limited accuracy.
Fuqi Ma   +4 more
wiley   +1 more source

Research on DC component decay time constant of 1000 kV AC filter circuit breakers in UHV converter station

open access: yesThe Journal of Engineering, 2019
In hierarchically connected UHV DC projects, the 1000 kV AC filter sub-bank in converter station is provided with two 500 kV circuit breakers. To determine the test DC component decay time constant when breakers break short-circuit current, relevant DC ...
Li Zhenqiang   +3 more
doaj   +1 more source

New topology for voltage balancing in railway substations

open access: yes, 2012
This paper deals with a new technique of voltage unbalance compensation for single phase railway substations. Using the concept of Chopper Controlled Impedance, the authors study the feasibility of an active Steinmetz circuit based on AC choppers.
New topology for voltage balancing in railway substations Raimondo G   +3 more