Results 61 to 70 of about 19,032 (231)
Development of online monitor for substation 10 kV MOA
Metal oxide arresters (MOA) are widely used for over-voltage protection of power facilities in 10 kV distribution networks, and it is hard to determine the failure ones. This study presented an online monitor for 10 kV MOA used in substation.
Xinming Song +4 more
doaj +1 more source
ABSTRACT Strong wind–sand weather in Xinjiang threatens power grid safety by increasing transmission line tripping risks. Existing studies focus on sand polarization but neglect the coupled influence of high‐speed airflow and charged sand on gap discharge characteristics.
Jianghai Geng +8 more
wiley +1 more source
The studies on strategies for improving restoration times in electrical distribution systems are extensive. They have theoretically explored the application of mathematical models, the implementation of remotely controlled systems, and the use of digital
Carlos Sánchez-Ixta +3 more
doaj +1 more source
ABSTRACT The thermal state of underground power cables can be monitored based on the temperature dependency of the dielectric permittivity of the insulation material. The resulting temperature‐dependent wave velocity is used as a thermometric property. To this end, the signal propagation time along a cable of an injected signal is determined.
Peter Wouters +2 more
wiley +1 more source
Research on optimisation of minimum air clearance of 1000 kV UHV AC substation
Based on air clearance discharge characteristic curve and insulation coordination method, it is pointed out that the minimum air clearance of 1000 kV ultra-high voltage (UHV) AC substation can be further optimised.
Li Zhenqiang +3 more
doaj +1 more source
ABSTRACT Heavy construction machinery is essential for power infrastructure construction and maintenance, making safety distance measurement crucial for ensuring operational safety. Existing methods, which rely on target space mapping, face challenges such as error accumulation and limited accuracy.
Fuqi Ma +4 more
wiley +1 more source
In hierarchically connected UHV DC projects, the 1000 kV AC filter sub-bank in converter station is provided with two 500 kV circuit breakers. To determine the test DC component decay time constant when breakers break short-circuit current, relevant DC ...
Li Zhenqiang +3 more
doaj +1 more source
ABSTRACT This paper provides an overview of high‐temperature superconducting (HTS) cables in DC systems, with a focus on their deployment in high‐voltage DC (HVDC) networks. The assessment of HTS cable properties—such as extremely low electrical resistance, high current‐carrying capacity and a compact geometry—and their comparison with those of ...
Mohammad Hossein Mousavi +2 more
wiley +1 more source
New topology for voltage balancing in railway substations
This paper deals with a new technique of voltage unbalance compensation for single phase railway substations. Using the concept of Chopper Controlled Impedance, the authors study the feasibility of an active Steinmetz circuit based on AC choppers.
New topology for voltage balancing in railway substations Raimondo G +3 more
core
STANDARDS IN CONTROL AND PROTECTION TEHNOLOGY FOR ELECTRIC POWER SYSTEMS [PDF]
The features of the standard IEC 16850 with respect to intelligent applications in substations are summarized. It is shown how modeling of functions independently from its allocation to devices allows optimizing existing applications and opening up for ...
Sergiu St. ILIESCU +3 more
core +2 more sources